Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

SWC4-plus

Engineering summary from PDF text extraction for SWC4-plus. Verify every value with the OEM datasheet.

Summary

Product identification

  • Membrane Element: SWC4+
  • Configuration Type: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Nominal Membrane Area: 400 ft²

Performance

  • Permeate Flow: 6,500 gpd (24.6 m³/d)
  • Nominal Rejection: 99.8 %
  • Minimum Rejection: 99.7 %

Performance is initial (data taken after 30 minutes of operation), based on the following conditions:

  • 32,000 ppm NaCl
  • 800 psi (5.5 MPa) Applied Pressure
  • 77 °F (25 °C) Operating Temperature
  • 10% Permeate Recovery
  • 6.5 - 7.0 pH Range

Operating limits

  • Maximum Applied Pressure: 1200 psig (8.27 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Feedwater pH Range: 3.0 - 10.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 75 GPM (17.0 m³/h)
  • Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
  • Maximum Pressure Drop for Each Element: 10 psi

The limitations shown are for general use; values may be more conservative for specific projects.

Mechanical / hydraulic

  • A (length): 40.0 inches (1016 mm)
  • B (diameter): 7.95 inches (201.9 mm)
  • C (interconnector ID): 1.125 inches (28.6 mm)
  • Weight: 36 lbs. (16.4 kg)

Packaging

All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box. Permeate flow for individual elements may vary ± 15 percent.


Disclaimer: This summary is based on the provided text extract. The original PDF may contain additional figures, footnotes, or revisions not included here. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.