Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

SWC5-LD

Engineering summary from PDF text extraction for SWC5-LD. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: SWC5-LD
  • Configuration: Low Fouling Spiral Wound
  • Membrane Polymer: Composite Polyamide

Specified Performance

  • Permeate Flow: 9,000 gpd (34.1 m³/d)
  • Salt Rejection: 99.8% (99.7% minimum)

Test Conditions:

  • 32000 ppm NaCl solution
  • 800 psig (5.5 MPa) Applied Pressure
  • 77 °F (25 °C) Operating Temperature
  • 10% Permeate Recovery
  • 6.5 - 7.0 pH Range

(Permeate flow for individual elements may vary ±15 percent from the value specified.)

Operating Limits

  • Maximum Applied Pressure: 1200 psig (8.27 MPa)
  • Maximum Chlorine Concentration: < 0.1 ppm
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous (Cleaning): 2-11 (1-13)
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 85 gpm (19.3 m³/h)
  • Minimum Brine Flow: 12 gpm (2.7 m³/h)
  • Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)

Mechanical / Hydraulic

  • Membrane Active Area: 400 ft² (37.2 m²)
  • Feed Spacer: 34 mil (0.86 mm)

Element Details (Indicative values):

  • A: 40.0 inches (1016 mm)
  • B: 7.89 inches (200 mm)
  • C: 1.125 inches (28.6 mm)

Packaging: All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Disclaimer

This information is presented in good faith and in lieu of all warranties. All express or implied warranties, including the warranties of merchantability and fitness for a particular purpose, are hereby disclaimed and excluded. Hydranautics assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the appropriateness of Hydranautics' products for the user's specific end uses. Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.