Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

SWC6-8040

Engineering summary from PDF text extraction for SWC6-8040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product: SWC6-8040
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 400 ft² (37.2 m²)

Performance

Initial performance data (after 30 minutes of operation) based on low pressure conditions: 32,000 ppm NaCl, 600 psi (4.1 MPa) Applied Pressure, 77 F (25 C) Operating Temperature, 6.5 - 7.0 pH Range.

Low Pressure Performance

  • Permeate Flow: 6,000 gpd (22.7 m³/d)
  • Salt Rejection: 99.6% (99.4 % min)
  • Boron Rejection (Typical)†: 83.0% (when tested with 5.0 ppm Boron in feed solution)
  • Applied Pressure: 600 psi (4.1 MPa)

High Flow Performance

  • Permeate Flow: 12,000 gpd (45.5 m³/d)
  • Salt Rejection: 99.8 % (99.7 % min)
  • Boron Rejection (Typical)†: 91.0% (when tested with 5.0 ppm Boron in feed solution)
  • Applied Pressure: 800 psi (5.4 MPa)

Operating limits

  • Maximum Applied Pressure: 1200 psig (8.27 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 F (45 C)
  • pH Range, Continuous (Cleaning): 2-11 (1-13)
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 75 GPM (17.0 m³/h)
  • Minimum Ratio of Concentrate to Permeate Flow for any Element: 5:1
  • Maximum Pressure Drop for Each Element: 10 psi

Mechanical / hydraulic

  • Dimensions:
    • A: 40.0 inches (1016 mm)
    • B: 7.89 inches (200 mm)
    • C: 1.125 inches (28.6 mm)
  • Weight: 36 lbs. (16.4 kg)

Notice

Permeate flow for individual elements may vary +25% or -15%. Membrane active area may vary +/-4%. All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.


Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.