Back to Hydranautics Membranes
Hydranautics logo

Datasheet summary

SWC6-LD

Engineering summary from PDF text extraction for SWC6-LD. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: SWC6-LD
  • Configuration: Low Fouling Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 400 ft² (37.2 m²)
  • Feed Spacer: 34 mil (0.86 mm)
  • Packaging: All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Specified Performance

  • Low Pressure Performance:
    • Permeate Flow: 6,000 gpd (22.7 m³/d)
    • Salt Rejection: 99.6% (99.4% minimum)
    • Applied Pressure: 600 psi (4.1 MPa)
  • High Flow Performance:
    • Permeate Flow: 12,000 gpd (45.4 m³/d)
    • Salt Rejection: 99.8% (99.7% minimum)
    • Applied Pressure: 800 psi (5.5 MPa)

Test Conditions (for Specified Performance):

  • 32000 ppm NaCl solution
  • 600 psig (4.1 MPa) Applied Pressure (relevant to the low pressure performance)
  • 77 °F (25 °C) Operating Temperature
  • 10% Permeate Recovery
  • 6.5 - 7.0 pH Range

Note: Permeate flow for individual elements may vary +25 / -20 percent from the value specified. Performance is based on data taken after a minimum of 10 minutes of operation and normalized to standard conditions.

Mechanical / hydraulic

Element Details (Indicative values):

  • A: 40.0 inches (1016 mm)
  • B: 7.89 inches (200 mm)
  • C: 1.125 inches (28.6 mm)

Operating limits

  • Maximum Applied Pressure: 1200 psig (8.27 MPa)
  • Maximum Chlorine Concentration: < 0.1 ppm
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous (Cleaning): 2-11 (1-13)
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 85 gpm (19.3 m³/h)
  • Minimum Brine Flow: 12 gpm (2.7 m³/h)
  • Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)