Summary

Product identification

  • Product Name: SWC6 MAX
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 440 ft² (40.9 m²)

Specified Performance

The specified performance is based on data taken after a minimum of 10 minutes of operation. Permeate flow for individual elements may vary +25 / -15 percent from the value specified.

  • Low Pressure Performance:
    • Permeate Flow: 6,600 gpd (25 m³/d)
    • Salt Rejection: 99.6% (99.4% minimum)
    • Applied Pressure: 600 psi (4.1 MPa)
  • High Flow Performance:
    • Permeate Flow: 13,200 gpd (50 m³/d)
    • Salt Rejection: 99.8% (99.7% minimum)
    • Applied Pressure: 800 psi (5.4 MPa)

Test Conditions (for normalization)

  • NaCl solution concentration: 32000 ppm
  • Applied Pressure: 600 psig (4.1 MPa)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6.5 - 7.0

Operating limits

  • Maximum Applied Pressure: 1200 psig (8.27 MPa)
  • Maximum Chlorine Concentration: < 0.1 ppm
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous (Cleaning): 2-11 (1-13)
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 75 gpm (17.0 m³/h)
  • Minimum Brine Flow: 12 gpm (2.7 m³/h)
  • Maximum Pressure Drop for Each Element: 15 psi (0.10 MPa)

Mechanical / hydraulic

  • Element Dimensions:
    • A: 40.0 inches (1016 mm)
    • B: 7.89 inches (200 mm)
    • C: 1.125 inches (28.6 mm)

Packaging

All membrane elements are supplied with a brine seal, interconnector, and O-rings. Elements are enclosed in a sealed polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Disclaimer: The information and data are presented in good faith and in lieu of all warranties. All express or implied warranties, including the warranties of merchantability and fitness for a particular purpose, are hereby disclaimed and excluded. Conditions and methods of use of products are beyond our control. Hydranautics assumes no liability for results obtained or damages incurred through the application of the presented information and data. It is the user's responsibility to determine the appropriateness of Hydranautics' products for the user's specific end uses. Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.