Datasheet summary
3838 HFM 180
Engineering summary from PDF text extraction for 3838 HFM 180. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: FM-180 FOOD & DAIRY UF ELEMENTS, Sanitary Ultrafiltration Spiral Elements
- Membrane Chemistry: Proprietary semi-permeable polyvinylidene difluoride (PVDF)
- Membrane Type: HFM-180 with observed separation range of 100,000 daltons
- Construction: Sanitary spiral wound element with polysulfone permeate tube and net outer wrap
- Regulatory Status: Compliant with US FDA CFR Title 21.
Options available for HFM-180 elements
- Diameter: 3.8”, 4.3”, 6.3”, or 8.3”
- Length: 33” or 38”
- Feed Spacer: N (31 mil), V (46 mil) or F (80 mil)
- Outer wrap: Controlled (e.g. NYV) or trimmable (e.g. NYT)
Specifications for 3838 HFM-180
- Active Membrane Area: 49 ft² (4.6 m²) with HYV/T Spacer (62 mil)
Operating limits
- Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar)
- Maximum Operating Pressure: 140 psi (9.7 bar)
- Recommended Operating Temperature Range: 41 - 130°F (5 - 54°C)
- Maximum Operating Temperature:
- At pH 6.0 - 7.5: 150°F (65.5°C)
- At pH 3.5 - 6.0: 140°F (60°C)
- At pH 2.0 - 3.5 and 7.5 – 10.0: 130°F (54°C)
- Cleaning Temperature Range: 105 - 130°F (40 - 54°C)
- Allowable pH - Continuous Operation: 2.5 - 10.5
- Allowable pH - Clean-In-Place (CIP): 1.5 - 11.0
- Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane.
- Design Pressure Drop Per Element:
- N spacer: 12-15 psi (0.8-1.0 bar)
- V spacer: 15-20 psi (1.0-1.4 bar)
- H or F spacer: 15-25 psi (1.0-1.7 bar)
- Design Pressure Drop Per Vessel (3 in series):
- N spacer: 36-45 psi (2.5-3.1 bar)
- V spacer: 45-60 psi (3.1-4.1 bar)
- H or F spacer: 45-75 psi (3.1-5.2 bar)
- Design Pressure Drop Per Vessel (4 in series):
- N spacer: 48-60 psi (3.3-4.1 bar)
- V spacer: 60-75 psi (4.1-5.2 bar)
- H or F spacer: 45-75 psi (3.1-5.2 bar)
- Chlorine Exposure during CIP:
- Recommended exposure time: 30 minutes per day.
- Residual chlorine concentration: 150 ppm @ pH 10.5 or higher.
- Maximum chlorine concentration: 200 ppm.
- Chlorine should only be added after pH has been adjusted to 10.5 or higher.
- Chemical Incompatibilities: Exposure to cationic (positively charged) polymers or surfactants is not recommended and will void the warranty. Iron or other catalyzing metals in the presence of free chlorine or hydrogen peroxide will accelerate membrane degradation.
- Lubricants: Use only water or glycerin to lubricate seals during installation. Petroleum or vegetable-based oils or solvents may damage the element and void the warranty.
Product water
- Pure water flux: 2.0-4.0 gfd/psi (50-100 l/m²/h/bar) at 77°F (25°C).
Mechanical / hydraulic
- Nominal Dimensions for 3838 HFM-180:
- Length (A): 38.0 inches (965 mm)
- Diameter (B): 3.8 inches (96 mm)
- Center Tube ID (C): 0.831 inches (21.1 mm)