Back to RO Membranes
Kovalus logo

International brand dossier

Koch Membrane Systems / Fluid Systems™

Koch Membrane Systems / Fluid Systems is now best understood through Kovalus Separation Solutions.

Brand profile and portfolio

Koch Membrane Systems / Fluid Systems is now best understood through Kovalus Separation Solutions.Fluid Systems is a pioneer of spiral membrane technology and notes that Koch Membrane Systems acquired Fluid Systems in 1998, so these records are important for legacy RO/NF elements, spiral-wound technology, and industrial process separations.

Koch Membrane Systems / Fluid Systems™'s position in RO/NF membranes and related equipment is defined by product families such as Sea Water RO Elements, Brackish Water Elements, Cellulose Acetate Elements and Ultrafiltration Cartridges / Hollow Fiber.

The portfolio is best understood inside brackish water, seawater desalination, ultrapure water, process separation, reuse, degassing, and membrane system packaging, where engineers compare the technology route, family boundaries, and duty fit before narrowing to individual models.Representative series on this page include TFC-4040-SW 4" High Rejection, TFC-18061-SW-3050 High Rejection and TFC-4040-HF 4" High Rejection, High Flow.

117

Models and series

12

Product families

Model index

Quick Model Index

117 models and series

Search specifications and compare candidates with products from other brands in the same category.

Products & documents
Filter by numeric range

Uses the displayed unit. Missing specifications, ranges and test conditions are excluded from scalar filters.

Showing 117 of 117 models

Compare 2–4 compatible models across brands. Your shortlist is saved on this device.

Ask with selected models

TFC-4040-SW 4" High Rejection

Sea Water RO Elements

Chloride Rejection: 99.75 percent · Permeate Flow: 1,330 gpd (5.0 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition)

This is a high rejection, seawater reverse osmosis (RO) membrane element from Koch Membrane Systems, constructed with a proprietary TFC polyamide membrane in a spiral...

DetailsPDF

TFC-18061-SW-3050 High Rejection

Sea Water RO Elements

Chloride Rejection percent: 99.75 · Permeate Flow gpd (m³/d): 53,000 (200) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This is a high rejection, seawater reverse osmosis membrane element designed for seawater desalination applications.

DetailsPDF

TFC-4040-HF 4" High Rejection, High Flow

Sea Water RO Elements

Chloride Rejection percent: 99.7 · Permeate Flow gpd (m³/d): 1,760 (6.6) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

Membrane Chemistry:Proprietary TFC® polyamide、Membrane Type:TFC®-HF membrane、Construction:Spiral wound with fiberglass outerwrap、Applications:Seawater desalination.

DetailsPDF

TFC-8040-HF-400 8" High Rejection, High Flow

Sea Water RO Elements

Chloride Rejection: 99.7% · Permeate Flow: 9,500 gpd (36.0 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line, and during transition)

This TFC-8040-HF-400 is an 8" high rejection, high flow seawater RO membrane element for desalination applications.

DetailsPDF

TFC SW MegaMagnum / 18061 SW 3050

Sea Water RO Elements

Chloride Rejection: 99.75 percent · Permeate Flow: 53,000 gpd (200 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition)

This is a high rejection, seawater reverse osmosis element with a proprietary TFC® polyamide membrane, constructed with a spiral wound design and helical fiberglass...

DetailsPDF

TFC HF MegaMagnum / 18061 HF 3050

Sea Water RO Elements

Chloride Rejection percent: 99.7 · Permeate Flow gpd (m³/d): 69,500 (263) · Permeate pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition)

The TFC HF MegaMagnum / 18061 HF 3050 is a high-rejection, high-flow seawater reverse osmosis membrane element.

DetailsPDF

TFC-2822 SS-300, 8" High Rejection, High Flow

Sea Water RO Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Typical operating pressure: 750–950 psi (5,175–6,555 kPa) · Maximum operating pressure: 1,200 psi (8,275 kPa)

The TFC-2822 SS-300 is a premium seawater reverse osmosis membrane element with a proprietary TFC polyamide membrane chemistry.

DetailsPDF

TFC

Sea Water RO Elements

Chloride Rejection (nominal): 99.6% · Minimum Rejection: 99.3% · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition)

These Koch Membrane Systems TFC-SS elements are high rejection, seawater reverse osmosis membrane elements constructed with proprietary TFC polyamide and a fiberglass...

DetailsPDF

TFC-8040-SR100-260 Low Pressure Nanofiltration

Sea Water RO Elements

MgSO₄ Rejection: > 99.0 percent · Nominal Permeate Flow: 4,500 gpd (17.0 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This is a low-pressure, selective rejection nanofiltration element from Koch Membrane Systems' FLUID SYSTEMS® TFC® SR100 line, designed for separating components over 200...

DetailsPDF

TFC-8040-SR100-400 Low Pressure Nanofiltration

Sea Water RO Elements

Rejection (MgSO₄): > 99.0 percent · Nominal Permeate Flow: 6,200 gpd (23.5 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This is a low-pressure, selective rejection nanofiltration membrane element from Koch Membrane Systems.

DetailsPDF

TFC-4040-HR 4" Hig Rejection, Low Pressure

Brackish Water Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Typical Operating Pressure: 150 - 250 psi (1,035 - 1,725 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

This is a high rejection, low pressure reverse osmosis membrane element for brackish water treatment.

DetailsPDF

TFC-8040-HR-375 8" High Rejection, Low Pressure

Brackish Water Elements

Chloride Rejection: 99.55 percent · Permeate Flow: 10,200 gpd (38.6 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This TFC® HR 8-inch element is designed for high rejection of brackish water using proprietary polyamide TFC® membrane chemistry.

DetailsPDF

TFC-8040-HR-400-34 8" High Rejection, High Area

Brackish Water Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line, and during transition) · Typical Operating Pressure: 150 - 250 psi (1,035 - 1,725 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

This TFC-8040-HR-400-34 is an 8-inch high rejection, high area reverse osmosis element designed for brackish water treatment.

DetailsPDF

TFC-18061-HR-2850 High Rejection, Low Pressure

Brackish Water Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition) · Typical Operating Pressure: 150 - 350 psi (1,035 - 2,400 kPa) · Maximum Operating Pressure: 450 psi (3,100 kPa)

These are high rejection, low pressure reverse osmosis elements designed for brackish water treatment with proprietary TFC® polyamide membrane chemistry.

DetailsPDF

TFC-4040-XR 4" High Rejection, Low Pressure

Brackish Water Elements

Chloride Rejection: 99.75% · Permeate Flow: 2,200 gpd (8.3 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This is a high rejection, low pressure RO element from Koch Membrane Systems designed for brackish water treatment.

DetailsPDF

TFC-8040-XR-375 8" Hig Rejection, Low Pressure

Brackish Water Elements

Permeate Pressure: Permeate pressure should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line, and during transition) · Typical Operating Pressure: 225 - 450 psi (1,550 - 3,100 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

The TFC-8040-XR-375 is an 8" high rejection, low pressure reverse osmosis element designed for brackish water treatment with a proprietary TFC® polyamide membrane.

DetailsPDF

TFC-4040-FR 4" High Rejection, Fouling Resistant, Low Pressure

Brackish Water Elements

Chloride Rejection: 99.55 percent (nominal) · Permeate Flow: 2,270 gpd (8.6 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line, and during transition)

TFC-4040-FR 4" High Rejection, Fouling Resistant, Low Pressure is a reverse-osmosis membrane element for selection by feed type, target water quality, membrane area, and...

DetailsPDF

TFC-8040-FR-375 8" High Rejection, Fouling Resistant, Low Pressure

Brackish Water Elements

Chloride Rejection: 99.55% · Typical Operating Pressure: 150 - 250 psi (1,035 - 1,725 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

This Koch Membrane Systems TFC-8040-FR-375 is an 8-inch high rejection, fouling-resistant, low-pressure RO element for brackish water treatment.

DetailsPDF

TFC 8822 FR-365

Brackish Water Elements

Chloride Rejection: 99.5 percent · Applied pressure: 225 psi (1,550 kPa) · Typical operating pressure: 225 - 450 psi (1,550 - 3,100 kPa)

This TFC 8822 FR-365 is a low-pressure, fouling-resistant reverse osmosis membrane element for brackish surface water or wastewater treatment.

DetailsPDF

TFC 8822 HR-365

Brackish Water Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Typical Operating Pressure: 150 - 250 psi (1,035 – 1,725 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

This TFC-HR 8” element is designed for brackish water treatment with high rejection capabilities.

DetailsPDF

TFC 8822 HR-400

Brackish Water Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time (on-line, off-line and during transition) · Typical Operating Pressure: 150 - 250 psi (1,035 – 1,725 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

This is a high rejection, low pressure RO membrane element from the FLUID SYSTEMS® TFC® HR 8” ELEMENTS product line, designed for brackish water treatment.

DetailsPDF

TFC 8832 HR-575 Magnum

Brackish Water Elements

Chloride Rejection: 99.5% · Permeate Flow: 15,000 gpd (56.8 m³/d) · Permeate Pressure Limit: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa)

This TFC 8832 HR-575 Magnum is a high-rejection, low-pressure reverse osmosis membrane element designed for brackish water treatment.

DetailsPDF

TFC 9822 HR-400

Brackish Water Elements

Nominal Chloride Rejection: 99.5% · Minimum Chloride Ion Rejection: 99.2% at test conditions · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

Koch Membrane Systems TFC 9822 HR-400 is an 8-inch reverse osmosis element designed for brackish water treatment with proprietary TFC®-HR polyamide membrane.

DetailsPDF

TFC 8822 XR-365

Brackish Water Elements

Minimum MgSO₄ Rejection: 99.4% (at the specified test conditions) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Typical Operating Pressure: 225-450 psi (1,550 – 3,100 kPa)

The FLUID SYSTEMS® TFC®-XR 8” ELEMENT is an extra high rejection, brackish water reverse osmosis membrane element with proprietary TFC polyamide chemistry.

DetailsPDF

TFC 8822 XR-400

Brackish Water Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Typical Operating Pressure: 225-450 psi (1,550 – 3,100 kPa) · Maximum Operating Pressure: 600 psi (4,140 kPa)

This is an extra high rejection, brackish water reverse osmosis membrane element with a proprietary TFC polyamide membrane.

DetailsPDF

TFC-8040-S-410 8"

Cellulose Acetate Elements

Chloride Rejection: 85% · MgSO₄ Rejection: 99.0% · Permeate Flow: 7,800 GPD (29.5 m³/d)

This TFC®-S 8” element is a low-pressure RO membrane for municipal water softening and THMFP reduction.

DetailsPDF

TFC 8923 S 400/ Softening / Low pressure

Cellulose Acetate Elements

Minimum chloride ion rejection: 85% · Minimum total hardness rejection: 94% (at mixed feed conditions) · Minimum MgSO₄ rejection: 95% (at MgSO₄ conditions)

The Koch Membrane Systems TFC 8923 S 400 is a reverse osmosis membrane element designed for municipal water softening and trihalomethane formation potential reduction.

DetailsPDF

TFC 8933 S 575 Magnum / Softening / Low pressure

Cellulose Acetate Elements

Nominal Permeate Flow: 12,500 gpd (47.3 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Membrane Area: 575 ft² (53.4 m²)

This Koch Membrane Systems TFC-S 8" Magnum element is a spiral-wound reverse osmosis membrane designed for softening and low-pressure applications.

DetailsPDF

ROGA-4040-HR 4"

Cellulose Acetate Elements

Chloride Rejection: 98.0 percent · Permeate Flow: 1,700 gpd (6.4 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

ROGA-4040-HR 4" is a reverse-osmosis membrane element for selection by feed type, target water quality, membrane area, and operating pressure.

DetailsPDF

ROGA-8040-HR-325 8"

Cellulose Acetate Elements

Chloride Rejection percent: 98.0 · Permeate Flow gpd (m³/d): 7,100 (26.9) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This ROGA-8040-HR-325 is an 8-inch spiral wound reverse osmosis membrane element with a proprietary cellulose acetate membrane chemistry.

DetailsPDF

ROGA-8040-UF-325 8"

Cellulose Acetate Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Membrane Area ft² (m²): 325 (30.2) · Typical Operating Pressure: 50-75 psi (345 - 515 kPa)

The Fluid Systems ROGA-UF 8" element is a cellulose acetate ultrafiltration membrane designed for RO pretreatment and water supply applications.

DetailsPDF

ROGA-HR8 / ROGA-8040-HR-325 / 8232 HR Magnum

Cellulose Acetate Elements

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Maximum differential pressure per vessel: 60 psi (414 kPa) · Single element recovery: approximately 15% for 40” (1,016 mm) long elements; 20% for 60” (1,524 mm) long elements

The ROGA-8040-HR-325 is an 8-inch cellulose acetate reverse osmosis membrane element designed for high rejection applications in municipal and industrial water treatment.

DetailsPDF

Romicon 1" PM5 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) (Permeate pressure should not exceed this at any time, including backflush.) · Maximum Operating Pressure: 40 psi (2.8 bar) (or 100 psi if permeate side is pressurized) · Maximum Transmembrane Pressure: 30 psi (2.1 bar)

The Romicon 1" PM5 Hollow Fiber cartridge is an ultrafiltration element designed for process streams with a 5,000 Dalton molecular weight cutoff, featuring a polysulfone...

DetailsPDF

Romicon 3" PM5 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Permeate Connection: 1½” T/C · Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) at any time, including backflush · Maximum Operating Pressure: 40 psi (2.8 bar), or 100 psi if the permeate side is pressurized. Actual operating pressure depends on feed stream, recovery, and temperature conditions

The Romicon 3" PM5 Hollow Fiber is a 3-inch diameter ultrafiltration cartridge designed for process streams with a 5,000 Dalton molecular weight cutoff.

DetailsPDF

Romicon 5" PM5 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) · Permeate Connection: 1 1/2” NPSM · Maximum Inlet Pressure: 40 psi (2.8 bar)

The Romicon 5" PM5 is a hollow fiber ultrafiltration cartridge made with polysulfone membrane and housing.

DetailsPDF

Romicon 6" PM5 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) · Permeate Connection: 1½” sanitary · Membrane Area: 97 ft² (9.0 m²)

This Romicon 6" PM5 is a hollow fiber cartridge designed for ultrafiltration, featuring a polysulfone membrane and housing construction.

DetailsPDF

Romicon HF 5043-66-45-XM50

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) · Permeate Connection: 1 1/2” NPSM · Membrane Area: 66 ft² (6.1 m²)

This industrial hollow fiber ultrafiltration module is designed for wastewater treatment and features an acrylonitrile co-polymer membrane.

DetailsPDF

Winefilter II 5043 Hollow Fiber Crossflow

Ultrafiltration Cartridges / Hollow Fiber

Permeate Connection: 1½” NPSM · Recommended Inlet Pressure: 20-30 psi (1.4-2.1 bar) · Maximum Transmembrane Pressure: 25 psi (1.7 bar)

The Winefilter II 5043 is a hollow fiber crossflow cartridge designed for wine filtration applications, featuring a polysulfone membrane and housing.

DetailsPDF

Winefilter II 6060 Hollow Fiber Crossflow

Ultrafiltration Cartridges / Hollow Fiber

Permeate Connection: 1 1/2” sanitary · Active Membrane Area: 130 ft² (12.1 m²) · Recommended Inlet Pressure: 40 psi (2.7 bar)

The Winefilter II 6060 is a 6-inch hollow fiber crossflow cartridge designed for wine filtration.

DetailsPDF

Winefilter II MF 5043 Hollow Fiber Crossflow

Ultrafiltration Cartridges / Hollow Fiber

Recommended Inlet Pressure: 20-30 psi (1.4-2.1 bar) · Maximum Transmembrane Pressure: 25 psi (1.7 bar) · Maximum Feed Side Pressure Drop: 25 psi (1.7 bar)

The Winefilter II MF 5043 is a hollow fiber microfiltration cartridge designed for wine filtration.

DetailsPDF

Winefilter II MF 6043 Hollow Fiber Crossflow

Ultrafiltration Cartridges / Hollow Fiber

Recommended Inlet Pressure: 40 psi (2.7 bar) · Maximum Transmembrane Pressure: 25 psi (1.7 bar) · Maximum Feed Side Pressure Drop: 30 psi (2.1 bar)

The Winefilter II MF 6043 is a hollow fiber crossflow microfiltration cartridge designed for wine filtration.

DetailsPDF

Super G Plus Module HFM 500

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Pressure: 5 psi (0.3 bar) · Maximum Operating Pressure: 90 psi @ 120°F (6.2 bar @ 49°C) · Minimum Outlet Pressure: 10 psi (0.7 bar)

This Koch Membrane Systems Super G Plus Module HFM 500 is an ultrafiltration multitube module designed for juice processing.

DetailsPDF

ABCOR INDUCOR 12 HFM 251 ICV

Ultrafiltration Cartridges / Hollow Fiber

Maximum permeate side back pressure: 3 psi (0.2 bar) · Membrane Area: 45.5 ft² (4.2 m²) · Maximum inlet pressure: 90 psi @ 119 °F (6.2 bar @ 48 °C)

The ABCOR INDUCOR 12 HFM 251 ICV is a reverse osmosis and nanofiltration membrane element with a PVDF neutral charge membrane.

DetailsPDF

ABCOR INDUCOR 10 HFM 251 ICV

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Side Back Pressure: 3 psi (0.2 bar) · Permeate Outlet: 1” Ø (2.54 cm) (2 per module, 180° aligned) · Membrane Area: 15.4 ft² (1.4 m²)

Product Name:ABCOR® - INDUCORTM-G MODULE: 10-HFM-251-ICV、Module Type:Industrial Multitubular Ultrafiltration Module、Part Number (KPN):0712501、Membrane...

DetailsPDF

Romipro 1" 1018-1.0-43-PM10 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Side Back Pressure: 20 psi (1.4 bar) · Maximum Inlet Pressure: 40 psi (2.8 bar) or 100 psi (if permeate side is pressurized) · Maximum Transmembrane Pressure: 35 psi (2.4 bar)

The Romipro 1" 1018-1.0-43-PM10 is a hollow fiber ultrafiltration cartridge designed for pharmaceutical applications with a polysulfone membrane and housing.

DetailsPDF

Spirapro HFK 4333-K131-VSV Pharmaceutical

Ultrafiltration Cartridges / Hollow Fiber

Permeate Tube: Stainless steel · Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar)

The Spirapro HFK 4333-K131-VSV is a pharmaceutical-grade ultrafiltration element featuring a proprietary polyethersulfone membrane with a 10,000 Dalton separation range.

DetailsPDF

Targa 8072-742-20-PM10 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Permeate Collection Tube: PVC · Maximum Pressure (water): 45 psi (3.0 bar) @ 104º F (40º C) or less · Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)

The Targa 8072-742-20-PM10 is an 8-inch industrial hollow fiber cartridge for ultrafiltration applications.

DetailsPDF

Targa 8048-238-43-PM100 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Permeate flow: 15.2 (3.4) - 7.1 (1.6) gpm (m³/hr) · Permeate Collection Tube: PVC · Maximum Pressure (water): 45 psi (3.0 bar) @ 104º F (40º C) or less

The Targa 8048-238-43-PM100 is an 8-inch industrial ultrafiltration hollow fiber cartridge with a proprietary polysulfone membrane chemistry and 100,000 nominal molecular...

DetailsPDF

Targa II 8048-35 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

O-Ring, Permeate Adapter: 8 each · Permeate Adapter: 2 each · Permeate Collection Tube: PVC

The Targa II 8048-35 is an 8-inch hollow fiber cartridge for water ultrafiltration.

DetailsPDF

Targa II 10048-35 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Permeate Collection Tube: PVC · Maximum Pressure (water): 45 psi (3.0 bar) @ 104°F (40°C) or less · Maximum Production Transmembrane Pressure: 30 psi (2.1 bar)

The Targa II 10048-35 is a 10-inch hollow fiber ultrafiltration cartridge with a proprietary semi-permeable polyethersulfone membrane.

DetailsPDF

Targa 8072-367-43-PM10 Hollow Fiber

Ultrafiltration Cartridges / Hollow Fiber

Membrane Area: 367 ft² (34.1 m²) · Permeate Collection Tube: PVC · Maximum Pressure (water): 45 psi (3.0 bar) @ 104º F (40º C) or less

The TARGA™ PM10 Hollow Fiber Cartridge is an 8-inch industrial ultrafiltration cartridge featuring a proprietary polysulfone membrane with a nominal MWCO of 10,000.

DetailsPDF

SUPER COR XL 3012 HFM 180

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Pressure: 3 psi (0.2 bar) · Membrane Area ft² (m²): 28.8 (2.7) · Maximum Operating Pressure: 90 psi @ 120°F (6.2 bar @ 49°C)

The SUPER COR XL 3012 HFM 180 is an ultrafiltration multitube module designed for juice processing applications.

DetailsPDF

SUPER COR XL PLUS 4312 MFK 180

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Pressure: 3 psi (0.2 bar) · Maximum Operating Pressure: 90 psi @ 120°F (6.2 bar @ 49°C) · Minimum Outlet Pressure: 10 psi (0.7 bar)

This Koch Membrane Systems ULTRAFILTRATION MODULE is designed for juice processing applications.

DetailsPDF

SUPER COR XL 3010 HFM 180

Ultrafiltration Cartridges / Hollow Fiber

Maximum Permeate Pressure: 3 psi (0.2 bar) · Membrane Area: 24 ft² (2.2 m²) · Maximum Operating Pressure: 90 psi @ 120°F (6.2 bar @ 49°C)

This Koch Membrane Systems SUPER COR XL 3010 HFM 180 is an ultrafiltration module utilizing PVDF membranes for juice processing.

DetailsPDF

SelRO 8040 MPS-34-NYHN

Microfiltration

Maximum Allowed Permeate Pressure: 3 psi (0.2 bar) · Typical Operating Pressure: 220-510 psi (15-35 bar) · Maximum Operating Pressure: 510 psi (35 bar)

This Koch Membrane Systems SelRO 8040 MPS-34-NYHN is a spiral wound nanofiltration element with a 200 Dalton MWCO, ideal for acid and caustic recovery.

DetailsPDF

SelRO MPS-34 2540 A2X

Microfiltration

Maximum Permeate Pressure: 3 psi (0.2 bar) · Permeate Tube Material: CPVC · Typical Operating Pressure: 220-510 psi (15-35 bar)

The SelRO MPS-34 is a pH-stable nanofiltration membrane element with a 200 Dalton molecular weight cut-off, suitable for acid and caustic recovery.

DetailsPDF

SelRO MPS-34-8040-B2X

Microfiltration

Permeate tube: B2 (stainless steel) or C2 (Polysulfone) · Maximum Allowed Permeate Pressure: 3 psi (0.2 bar) · Typical Operating Pressure: 220-510 psi (15-35 bar)

This SelRO MPS-34-8040-B2X is a pH stable nanofiltration membrane element with a 200 Dalton molecular weight cut-off for acid and caustic recovery applications.

DetailsPDF

SelRO 8038 MPS-34-ZYT

Microfiltration

Rejection (Glucose / Sucrose) [%]: 95 / 97 · Rejection (NaCl) [%]: 35 · Permeate Flow [gpd (m³/day)]: 7,800 (29.5)

This is an 8-inch spiral wound nanofiltration membrane element with a proprietary composite membrane and a molecular weight cut-off of 200 Daltons.

DetailsPDF

SelRO 8040 MPS-36-NYHN

Microfiltration

Maximum Permeate Pressure: 3 psi (0.2 bar) · Typical Operating Pressure: 220-510 psi (15-35 bar) · Maximum Operating Pressure: 510 psi (35 bar)

This SelRO 8040 MPS-36-NYHN is a nanofiltration spiral element with a proprietary composite membrane chemistry, designed for applications like acid and caustic recovery.

DetailsPDF

SelRO 3838 MPS-36-VYV

Microfiltration

Permeate Flow: 7,100 gpd (26.9 m³/d) · Maximum Allowed Permeate Pressure: 3 psi (0.2 bar) · Maximum Feed Flow Rate: 17 gpm (65 Liter per minute)

The SelRO 3838 MPS-36-VYV is a 4-inch acid and caustic stable nanofiltration membrane element for product concentration and purification.

DetailsPDF

Dairy-Pro 3838 NF-200-30

Microfiltration

Typical Operating Pressure: 200 - 450 psi (13.8 - 31.0 bar) · Maximum Operating Pressure: 800 psi (55 bar) · Design Pressure Drop Per Element: 6 - 10 psi (0.4 - 0.7 bar)

The Dairy-Pro NF-200 element is a sanitary spiral wound nanofiltration membrane for desalting and separation of proteins, sugars, and carbohydrates.

DetailsPDF

Spirapro 3838 SR3-NYV Pharmaceutical

Microfiltration

Typical Operating Pressure: 200 - 450 psi (13.8 - 31.0 bar) · Maximum Operating Pressure: 650 psi (44.8 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including online, off-line and during transition). Reverse pressure will damage the element

The Spirapro 3838 SR3-NYV is a sanitary spiral wound nanofiltration membrane element with a proprietary TFC polyamide chemistry for desalting and separation of...

DetailsPDF

Spirapro 8040 SR3-NYVP Pharmaceutical

Microfiltration

Rejection: 99.0% · Maximum Operating Pressure: 650 psi (44.8 bar) · Design Pressure Drop Per Element: 3 - 6 psi (0.2-0.4 bar)

This sanitary spiral wound nanofiltration element uses a proprietary TFC polyamide membrane with a 200 dalton molecular weight cut-off for desalting, concentration, and...

DetailsPDF

Dairy-Pro 3838 MF-0.1-45

Microfiltration

Typical Operating Pressure: 15 - 30 psi (1.0 - 2.1 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Design Pressure Drop Per Element: 5 - 20 psi (0.4 - 1.4 bar)

The Dairy-Pro 3838 MF-0.1-45 is a microfiltration spiral wound sanitary element with a proprietary PES membrane for applications like whey de-fatting and casein...

DetailsPDF

3838 MFK-601

Microfiltration

Active Area ft² (m²): 33 (3.1) · Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar)

This Koch Membrane Systems MFK™ FOOD & DAIRY MF ELEMENT is a 3.8-inch diameter microfiltration spiral element with a 0.4-micron separation range.

DetailsPDF

8338-MFK-601

Microfiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Must not exceed baseline (concentrate) pressure at any time; reverse pressure will damage the membrane

This Koch Membrane Systems MFK™ Food & Dairy microfiltration element features a proprietary polyethersulfone (PES) membrane with a 0.4-micron separation range.

DetailsPDF

8838 MFK-601

Microfiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane

The 8838 MFK-601 is a microfiltration spiral-wound element from Koch Membrane Systems with a proprietary polyethersulfone membrane layer for food and dairy applications.

DetailsPDF

3838 MFK-603-FYV

Microfiltration

Retention / pore size: 0.1 micron · Active Membrane Area ft² (m²): 33 (3.0) · Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar)

The 3838 MFK-603-FYV is a sanitary microfiltration element with a 0.1 micron separation range, constructed from proprietary polyethersulfone (PES) membrane.

DetailsPDF

8338-MFK-603-FYT

Microfiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time

The 8338-MFK-603-FYT is a sanitary spiral wound microfiltration membrane element with a proprietary polyethersulfone (PES) layer for food and dairy applications.

DetailsPDF

3838 MFK-618

Microfiltration

Retention / pore size: 0.1 micron · Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar)

The 3838 MFK-618 is a 4-inch microfiltration element with a proprietary semi-permeable polyethersulfone (PES) membrane offering 0.1 micron separation.

DetailsPDF

SUPER-COR 3010-MFK-617

Microfiltration

Retention / pore size: 0.1 micron · Maximum Permeate Pressure: 3 psi (0.2 bar) · Membrane Area: 24 ft² (2.2 m²)

The SUPER-COR 3010-MFK-617 is a microfiltration module featuring a polyethersulfone membrane with a nominal pore size of 0.1 micron.

DetailsPDF

SUPER-COR XL 3012-MFK-617

Microfiltration

Retention / pore size: 0.1 micron · Maximum Permeate Pressure: 3 psi (0.2 bar) · Nominal Pore Size: 0.1 micron

This is a Koch Membrane Systems SUPER-COR XL microfiltration module designed for juice processing with a 0.1 micron polyethersulfone membrane.

DetailsPDF

SUPER-COR XL PLUS 4312-MFK-6

Microfiltration

Maximum Permeate Pressure: 3 psi (0.2 bar) · Nominal Pore Size: 0.1 micron · Membrane Area: 54.7 ft² (5.1 m²)

The SUPER-COR XL PLUS 4312-MFK-6 is a microfiltration membrane module designed for juice processing.

DetailsPDF

Dairy-NF 3838 SR3D-NYV

Food & Dairy UF / NF RO Elements

Typical Operating Pressure: 200 - 450 psi (13.8 - 31.0 bar) · Maximum Operating Pressure: 650 psi (44.8 bar) · Design Pressure Drop Per Element: 6 - 10 psi (0.4 - 0.7 bar)

This Koch Membrane Systems SR3D sanitary nanofiltration element is designed for desalting and separation of proteins, sugars, and carbohydrates.

DetailsPDF

Dairy-UF 3838 HFK-131

Food & Dairy UF / NF RO Elements

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane

The Dairy-UF 3838 HFK-131 is a sanitary spiral wound ultrafiltration membrane element with a proprietary polyethersulfone layer and a 10,000 Dalton separation range.

DetailsPDF

Dairy-UF 3838 HFM-180-VYV

Ultrafiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including on-line, off-line and during transition). Reverse pressure will damage the membrane

This is a sanitary ultrafiltration spiral element with a proprietary PVDF membrane chemistry and a separation range of 100,000 daltons.

DetailsPDF

Spiral UF 7533-M183-VPF

Ultrafiltration

Maximum Permeate Pressure: 5 psi (0.3 bar) · Permeate Tube Outside Diameter: 1.660 inches (42.2 mm) · Maximum Inlet Pressure: 80 psi @ 125°F (5.5 bar @ 52°C)

This Koch Membrane Systems Spiral Ultrafiltration Element is designed for cathodic electrocoat paint applications with a positive charge PVDF membrane.

DetailsPDF

POLISHING RO ELEMENT 8040 HRX-NYVP

Food & Dairy UF / NF RO Elements

Active Membrane Area: 371 ft² (34.5 m²) · Maximum Operating Pressure: 650 psi (44.8 bar) · Maximum Pressure During Cleaning: 150 psi (10.3 bar)

This Koch Membrane Systems 8040 HRX-NYVP is a high rejection reverse osmosis sanitary element designed for food and dairy polishing applications.

DetailsPDF

Dairy-UF HpHT 3838-K131-NYV

Ultrafiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane

This is a Koch Membrane Systems HpHT HFK-131 ultrafiltration spiral wound element with a proprietary polyethersulfone membrane.

DetailsPDF

Dairy-MF 3838 MFK-618-NYV

Food & Dairy UF / NF RO Elements

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane

This sanitary spiral wound microfiltration element is designed for food and dairy applications, featuring a proprietary polyethersulfone membrane.

DetailsPDF

Dairy-MF 3838 MFK-603-FYV

Food & Dairy UF / NF RO Elements

Retention / pore size: 0.1 micron · Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar)

This sanitary spiral wound membrane element utilizes a proprietary polyethersulfone (PES) MFK™-603 membrane with 0.1 micron separation for RO and NF applications.

DetailsPDF

Dairy-Pro 3838 RO - 30

Food & Dairy UF / NF RO Elements

Typical Operating Pressure: 300 - 600 psi (20.7 - 41.4 bar) · Maximum Operating Pressure: 800 psi (55 bar) · Design Pressure Drop Per Element: 6 - 10 psi (0.4 - 0.7 bar)

The Dairy-Pro 3838 RO - 30 is a sanitary spiral wound reverse osmosis membrane element designed for dairy processing applications like whey concentration.

DetailsPDF

Dairy-UF XL 3838 HFK-131-NYV

Food & Dairy UF / NF RO Elements

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including online, off-line, and during transition). Reverse pressure will damage the membrane

Koch Membrane Systems XL-1000 FOOD & DAIRY UF ELEMENTS are ultrafiltration (UF) spiral elements available in 4”, 6”, and 8” diameters, featuring patented Fused-Fold...

DetailsPDF

Dairy-Pro 6338 UF 5K/10K

Ultrafiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including on-line, off-line, and during transition). Reverse pressure will damage the membrane

The Koch Membrane Systems Dairy-Pro™ UF elements are sanitary spiral wound ultrafiltration membranes with proprietary polyethersulfone layers.

DetailsPDF

ABCOR FEG PLUS 10-HFM-251-PVI

Ultrafiltration

Maximum Permeate Side Back Pressure: 5 psi (0.3 bar) · Membrane Area: 2.2 ft² (0.20 m²) · Maximum Inlet Pressure: 90 psi @ 140°F (6.2 bar @ 60°C)

The ABCOR FEG PLUS 10-HFM-251-PVI is a tubular ultrafiltration module with a PVDF membrane, designed for industrial applications.

DetailsPDF

Spirapak 4033-HFM-183-LPP

Ultrafiltration

Maximum Permeate Pressure: 5 psi (0.3 bar) · Permeate and Process Connections: 1- ¼ NPSM · Membrane Area: 59 ft² (5.5 m²)

This Spirapak 4033-HFM-183-LPP is a spiral ultrafiltration module designed for cathodic electrocoat paint applications.

DetailsPDF

Spirapak 4033-HFM-183-VPP

Ultrafiltration

Maximum Permeate Pressure: 5 psi (0.3 bar) · Permeate connection Option #1 – 5/8” OD Rigid Tubing (Qty: 1, KPN: 0231208) · Permeate connection Option #2 – ½” ID Flex hose (Qty: 1, KPN: 0231207)

This Koch Membrane Systems SPIRAPAK™ module is a spiral ultrafiltration unit designed for cathodic electrocoat paint applications.

DetailsPDF

Spirapak 4033-HFM-300-VPP

Ultrafiltration

Maximum Permeate Pressure: 5 psi (0.3 bar) · Permeate and Process Connections: 1- ¼ NPSM · Permeate connection Option #1: 5/8” OD Rigid Tubing (KPN 0231208)

This Spirapak module is a spiral wound ultrafiltration membrane element with a PVDF HFM membrane chemistry and an integrated PVC housing.

DetailsPDF

Spirapak 4038-HFM-183-LPP3

Ultrafiltration

Maximum Permeate Pressure: 5 psi (0.3 bar) · Permeate Connection Options: The PDF lists three permeate connection options in the assembly section: 5/8” OD Rigid Tubing, ½” ID Flex hose, and 1½” Sanitary ferrule · Membrane Area: 78 ft² (7.2 m²)

This Spirapak 4038-HFM-183-LPP3 is a spiral ultrafiltration module with a positively charged PVDF membrane designed for cathodic electrocoat paint applications.

DetailsPDF

Spirapak 4038-HFM-183-VPP3

Ultrafiltration

Maximum Permeate Pressure: 5 psi (0.3 bar) · Permeate and Process Connections: 1- ¼ NPSM · Membrane Area: 63 ft² (5.9 m²)

This Koch Membrane Systems Spirapak module is a spiral ultrafiltration element designed for cathodic electrocoat paint applications.

DetailsPDF

3838 HFK-328

Ultrafiltration

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including on-line, off-line and during transition). Reverse pressure will damage the membrane

This Koch Membrane Systems HFK-328 is an ultrafiltration element with a proprietary polyethersulfone membrane, capable of separating molecules with a molecular weight of...

DetailsPDF

Kpak 8638-M-183-LPP

Ultrafiltration

Maximum Permeate Side Back Pressure: 5.0 psi (0.34 bar) · Permeate Tube I.D: 1.3 in (33.0 mm) · Membrane Area: 288 ft² (26.7 m²)

This PVDF spiral wound ultrafiltration module has a membrane area of 288 ft² and is designed for use with reverse osmosis and nanofiltration systems.

DetailsPDF

Kpak 8638-M-183-VPP

Ultrafiltration

Maximum Permeate Side Back Pressure: 5.0 psi (0.34 bar) · Permeate Tube I.D: 1.3 in (33.0 mm) · Membrane Area: 241 ft² (22.4 m²)

This Kpak 8638-M-183-VPP is an 8-inch spiral wound membrane element with PVDF HFM membrane chemistry for ultrafiltration applications.

DetailsPDF

Kpak 8638-M-300-LPP

Ultrafiltration

Maximum Permeate Side Back Pressure: 5.0 psi (0.34 bar) · Permeate Tube I.D: 1.3 in (33.0 mm) · Membrane Area: 288 ft² (26.7 m²)

This Kpak 8638-M-300-LPP is a spiral wound reverse osmosis/nanofiltration membrane element with PVDF HFM chemistry and an integrated PVC housing.

DetailsPDF

Kpak 10738-M-183-LPP

Ultrafiltration

Maximum Permeate Side Back Pressure: 5.0 psi (0.34 bar) · Permeate Tube I.D: 1.3 in (33.0 mm) · 1 Permeate Plug: PVC (KPN 1006162)

This is a Koch Membrane Systems Kpak 10738-M-183-LPP Zero Bypass E-Coat Ultrafiltration Spiral Module with a PVDF HFM membrane and 462 ft² of area.

DetailsPDF

Kpak 10738-M-300-LPP

Ultrafiltration

Maximum Permeate Side Back Pressure: 5.0 psi (0.34 bar) · Permeate Tube I.D: 1.3 in (33.0 mm) · Permeate Plug: 1 required, PVC (KPN 1006162)

This is a Kpak 10738-M-300-LPP Zero Bypass E-Coat Ultrafiltration Spiral Module with PVDF HFM membrane chemistry.

DetailsPDF

HpHT 3838-K131-NYV

Ultrafiltration

Selection cues: rejection · permeate flow · membrane area and operating pressure

This is a Koch Membrane Systems HpHT membrane element designed for high-temperature and high-pressure reverse osmosis and nanofiltration applications.

DetailsPDF

3838 HFM 180

Ultrafiltration

Selection cues: rejection · permeate flow · membrane area and operating pressure

The 3838 HFM 180 is a reverse osmosis membrane element designed for food and dairy applications.

DetailsPDF

7533-M183-VPF

Ultrafiltration

Selection cues: rejection · permeate flow · membrane area and operating pressure

This is a Koch Membrane Systems Fluid Systems™ spiral wound membrane element designed for reverse osmosis and nanofiltration applications.

DetailsPDF

Pulsion Puron Hollow Fiber Rows

Hollow Fiber Modules / MBR Applications

Nominal Pore Size: 0.03 µm · Membrane Area: 468 ft² (43.5 m²) · Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)

This Pulsion Puron hollow fiber row is a submerged membrane designed for MBR applications, featuring a proprietary PVDF membrane chemistry and polyester fiber support.

DetailsPDF

Pulsion Puron LE 8

Hollow Fiber Modules / MBR Applications

Nominal Pore Size: 0.03 µm · Permeate Collection Tube Material: ABS, PVC, PE manifolds · Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)

The Pulsion Puron LE 8 is a submerged hollow fiber membrane module designed for MBR applications, featuring a proprietary PVDF braided hollow fiber.

DetailsPDF

Puron PSH 250

Hollow Fiber Modules / MBR Applications

Nominal Pore Size: 0.03 µm · Permeate Collection Tube Material: ABS, PVC, PE manifolds · Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)

The Puron PSH 250 is a hollow fiber submerged membrane module designed for MBR applications, featuring a proprietary PVDF membrane chemistry.

DetailsPDF

Puron PSH 31HD

Hollow Fiber Modules / MBR Applications

Nominal Pore Size: 0.03 µm · Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar) · Maximum Backflush Transmembrane Pressure: 9 psi (0.6 bar)

The Puron PSH 31HD is a hollow fiber submerged membrane row designed for MBR applications, featuring a proprietary PVDF membrane chemistry.

DetailsPDF

Puron PSH 95

Hollow Fiber Modules / MBR Applications

Retention / pore size: 0.03 µm · Nominal Pore Size: 0.03 µm · Permeate Collection Tube Material: ABS, PVC, PE manifolds

The Puron PSH 95 is a submerged hollow fiber membrane module for MBR applications featuring a proprietary PVDF membrane with a nominal pore size of 0.03 µm.

DetailsPDF

Puron PSH 330

Hollow Fiber Modules / MBR Applications

Nominal Pore Size: 0.03 µm · Permeate Collection Tube Material: ABS, PVC, PE manifolds · Maximum Filtration Transmembrane Pressure: 9 psi (0.6 bar)

The Puron PSH 330 is a submerged hollow fiber membrane module designed for MBR applications, featuring a proprietary PVDF membrane chemistry.

DetailsPDF

Puron PHF 480

Hollow Fiber Modules / MBR Applications

Nominal Pore Size: 0.03 µm · Permeate Collection Tube Material: ABS, PVC, PE manifolds · Maximum Filtration Transmembrane Pressure: 11.5 psi (0.8 bar)

The Puron PHF 480 is a hollow fiber submerged membrane module utilizing proprietary PVDF for water and wastewater treatment.

DetailsPDF

KMS 3838 HRX-NYV

Surface Water

Typical Operating Pressure: 300 - 600 psi (20.7 – 41.4 bar) · Maximum Operating Pressure: 650 psi (44.8 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including online, off-line and during transition). Reverse pressure will damage the element

The KMS 3838 HRX-NYV is a high rejection reverse osmosis membrane element with proprietary TFC® polyamide chemistry.

DetailsPDF

TFC-FR8 / TFC 8822 FR-365

Surface Water

Chloride Rejection: 99.5% · Feed spacer thickness standard/high area: 31/28 mil (0.8/0.7 mm) · Typical operating pressure: 225 - 450 psi (1,550 - 3,100 kPa)

Koch Membrane Systems TFC® - FR 8-inch series elements are fouling-resistant, low-pressure brackish reverse osmosis membranes designed for surface water and wastewater...

DetailsPDF

TFC-FR8 / TFC 8822 FR-400

Surface Water

Feed spacer thickness standard/high area: 31/28 mil (0.8/0.7 mm) · Typical operating pressure: 225 - 450 psi (1,550 - 3,100 kPa) · Maximum operating pressure: 600 psi (4,140 kPa)

The TFC-FR8 / TFC 8822 FR-400 is a fouling-resistant, low-pressure reverse osmosis membrane element for brackish surface water or wastewater treatment.

DetailsPDF

TFC-FR8 / TFC 8832 FR-575 Magnum

Surface Water

Feed spacer thickness standard/high area: 31/28 mil (0.8/0.7 mm) · Typical operating pressure: 225 - 450 psi (1,550 - 3,100 kPa) · Maximum operating pressure: 600 psi (4,140 kPa)

The TFC-FR8 / TFC 8832 FR-575 Magnum is a fouling-resistant reverse osmosis membrane element designed for surface water and wastewater treatment.

DetailsPDF

HpHT 3838 UF K328/K131 - 30

Sanitairy UF Elements

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time. Reverse pressure will damage the membrane

The HpHT 3838 UF K328/K131 is a sanitary ultrafiltration element with a proprietary semi-permeable polyethersulfone membrane.

DetailsPDF

Dairy-Pro HpHT 3838 UF 5K/10K - 80

Sanitairy UF Elements

Typical Operating Pressure: 30 - 120 psi (2.1 - 8.3 bar) · Maximum Operating Pressure: 140 psi (9.7 bar) · Permeate Pressure: Should not exceed baseline (concentrate) pressure at any time (including on-line, off-line and during transition). Reverse pressure will damage the membrane

The Dairy-Pro HpHT UF 5K/10K is a sanitary ultrafiltration spiral wound element designed for dairy processing with a proprietary polyethersulfone membrane.

DetailsPDF

8823 ULP-400

Polishing Water

Chloride Rejection percent: 98.5 · Permeate Flow gpd (m³/d): 8,500 (32.2) · Permeate pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This Koch Membrane Systems (Fluid Systems™) 8823 ULP-400 is an ultra-low pressure reverse osmosis membrane element for potable water production.

DetailsPDF

TFC 4040-ULP

Polishing Water

Chloride Rejection: 98.65 percent · Permeate Flow: 1,800 gpd (6.8 m³/d) · Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time

This ultra-low pressure reverse osmosis element uses a proprietary TFC polyamide membrane for light industrial and potable water production.

DetailsPDF

TFC 4040-ULP-T

Polishing Water

Permeate Pressure: Should not exceed feed-concentrate pressure by more than 5 psi (34 kPa) at any time · Typical Operating Pressure: 100 - 175 psi (690 - 1,208 kPa) · Maximum Operating Pressure: 350 psi (2,400 kPa)

The FLUID SYSTEMS® TFC®- ULP® 4” ELEMENT is an ultra-low pressure reverse osmosis (RO) element.

DetailsPDF

3838 HR-NYV

Polishing Water

Active Membrane Area ft² (m²): 76 (7.1) · Typical Operating Pressure: 300 - 600 psi (20.7 – 41.4 bar) · Maximum Operating Pressure: 650 psi (44.8 bar)

This reverse osmosis element is designed for sanitary food and dairy applications with proprietary TFC® polyamide membrane chemistry.

DetailsPDF

Spiral Wound Cataloque

Overview Koch Membranes

Selection cues: rejection · permeate flow · membrane area and operating pressure

This product is a range of spiral-wound membrane elements from Koch Membrane Systems for reverse osmosis and nanofiltration applications.

DetailsPDF
Product families and selection guidance

Product range and selection

How to choose Koch Systems / Fluid Systems™ RO Membranes

This section answers two questions: which main product families Koch Systems / Fluid Systems™ offers, and which parameters to compare before choosing a specific model.

Step 1: Choose a product family by application

The main families shown on this page are Sea Water RO Elements, Brackish Water Elements, Cellulose Acetate Elements, and Ultrafiltration Cartridges / Hollow Fiber. Start with the treatment objective, equipment format, and operating duty, then use the model index below to compare exact specifications.

Step 2: Confirm the model by key parameters

After choosing a product family, compare feed salinity, target salt rejection, permeate flow, operating pressure, fouling tendency, and element size and connection. Replacement projects should also verify installation or loading conditions, interfaces, and compatibility with the existing system; new projects should consider operating practice, maintenance, and spare-parts or consumables availability.

Product family overview

Showing 6 main families; all 12 appear in the model index below.

Sea Water RO Elements

10 models in this family. Representative models: TFC-4040-SW 4" High Rejection, TFC-18061-SW-3050 High Rejection, TFC-4040-HF 4" High Rejection, High Flow.

Brackish Water Elements

15 models in this family. Representative models: TFC-4040-HR 4" Hig Rejection, Low Pressure, TFC-8040-HR-375 8" High Rejection, Low Pressure, TFC-8040-HR-400-34 8" High Rejection, High Area.

Cellulose Acetate Elements

7 models in this family. Representative models: TFC-8040-S-410 8", TFC 8923 S 400/ Softening / Low pressure, TFC 8933 S 575 Magnum / Softening / Low pressure.

Ultrafiltration Cartridges / Hollow Fiber

22 models in this family. Representative models: Romicon 1" PM5 Hollow Fiber, Romicon 3" PM5 Hollow Fiber, Romicon 5" PM5 Hollow Fiber.

Microfiltration

19 models in this family. Representative models: SelRO 8040 MPS-34-NYHN, SelRO MPS-34 2540 A2X, SelRO MPS-34-8040-B2X.

Food & Dairy UF / NF RO Elements

7 models in this family. Representative models: Dairy-NF 3838 SR3D-NYV, Dairy-UF 3838 HFK-131, POLISHING RO ELEMENT 8040 HRX-NYVP.

Product introductions and documents

Brand Products & Technical Documents

117 models and series

View product applications, datasheets and family manuals.

Sea Water RO Elements

10 product profiles

RO
Kovalus logo

Product profile

TFC-4040-SW 4" High Rejection

This is a high rejection, seawater reverse osmosis (RO) membrane element from Koch Membrane Systems, constructed with a proprietary TFC polyamide membrane in a spiral...

RO
Kovalus logo

Product profile

TFC-18061-SW-3050 High Rejection

This is a high rejection, seawater reverse osmosis membrane element designed for seawater desalination applications.

RO
Kovalus logo

Product profile

TFC-4040-HF 4" High Rejection, High Flow

Membrane Chemistry:Proprietary TFC® polyamide、Membrane Type:TFC®-HF membrane、Construction:Spiral wound with fiberglass outerwrap、Applications:Seawater desalination.

RO
Kovalus logo

Product profile

TFC-8040-HF-400 8" High Rejection, High Flow

This TFC-8040-HF-400 is an 8" high rejection, high flow seawater RO membrane element for desalination applications.

RO
Kovalus logo

Product profile

TFC SW MegaMagnum / 18061 SW 3050

This is a high rejection, seawater reverse osmosis element with a proprietary TFC® polyamide membrane, constructed with a spiral wound design and helical fiberglass...

RO
Kovalus logo

Product profile

TFC HF MegaMagnum / 18061 HF 3050

The TFC HF MegaMagnum / 18061 HF 3050 is a high-rejection, high-flow seawater reverse osmosis membrane element.

Show remaining Sea Water RO Elements profiles (4)
RO
Kovalus logo

Product profile

TFC-2822 SS-300, 8" High Rejection, High Flow

The TFC-2822 SS-300 is a premium seawater reverse osmosis membrane element with a proprietary TFC polyamide membrane chemistry.

RO
Kovalus logo

Product profile

TFC

These Koch Membrane Systems TFC-SS elements are high rejection, seawater reverse osmosis membrane elements constructed with proprietary TFC polyamide and a fiberglass...

NF
Kovalus logo

Product profile

TFC-8040-SR100-260 Low Pressure Nanofiltration

This is a low-pressure, selective rejection nanofiltration element from Koch Membrane Systems' FLUID SYSTEMS® TFC® SR100 line, designed for separating components over 200...

NF
Kovalus logo

Product profile

TFC-8040-SR100-400 Low Pressure Nanofiltration

This is a low-pressure, selective rejection nanofiltration membrane element from Koch Membrane Systems.

Brackish Water Elements

15 product profiles

RO
Kovalus logo

Product profile

TFC-4040-HR 4" Hig Rejection, Low Pressure

This is a high rejection, low pressure reverse osmosis membrane element for brackish water treatment.

RO Membranes
Kovalus logo

Product profile

TFC-8040-HR-375 8" High Rejection, Low Pressure

This TFC® HR 8-inch element is designed for high rejection of brackish water using proprietary polyamide TFC® membrane chemistry.

RO
Kovalus logo

Product profile

TFC-8040-HR-400-34 8" High Rejection, High Area

This TFC-8040-HR-400-34 is an 8-inch high rejection, high area reverse osmosis element designed for brackish water treatment.

RO
Kovalus logo

Product profile

TFC-18061-HR-2850 High Rejection, Low Pressure

These are high rejection, low pressure reverse osmosis elements designed for brackish water treatment with proprietary TFC® polyamide membrane chemistry.

RO
Kovalus logo

Product profile

TFC-4040-XR 4" High Rejection, Low Pressure

This is a high rejection, low pressure RO element from Koch Membrane Systems designed for brackish water treatment.

RO
Kovalus logo

Product profile

TFC-8040-XR-375 8" Hig Rejection, Low Pressure

The TFC-8040-XR-375 is an 8" high rejection, low pressure reverse osmosis element designed for brackish water treatment with a proprietary TFC® polyamide membrane.

Show remaining Brackish Water Elements profiles (9)
RO
Kovalus logo

Product profile

TFC-4040-FR 4" High Rejection, Fouling Resistant, Low Pressure

TFC-4040-FR 4" High Rejection, Fouling Resistant, Low Pressure is a reverse-osmosis membrane element for selection by feed type, target water quality, membrane area, and...

RO
Kovalus logo

Product profile

TFC-8040-FR-375 8" High Rejection, Fouling Resistant, Low Pressure

This Koch Membrane Systems TFC-8040-FR-375 is an 8-inch high rejection, fouling-resistant, low-pressure RO element for brackish water treatment.

RO
Kovalus logo

Product profile

TFC 8822 FR-365

This TFC 8822 FR-365 is a low-pressure, fouling-resistant reverse osmosis membrane element for brackish surface water or wastewater treatment.

RO Membranes
Kovalus logo

Product profile

TFC 8822 HR-365

This TFC-HR 8” element is designed for brackish water treatment with high rejection capabilities.

RO
Kovalus logo

Product profile

TFC 8822 HR-400

This is a high rejection, low pressure RO membrane element from the FLUID SYSTEMS® TFC® HR 8” ELEMENTS product line, designed for brackish water treatment.

RO
Kovalus logo

Product profile

TFC 8832 HR-575 Magnum

This TFC 8832 HR-575 Magnum is a high-rejection, low-pressure reverse osmosis membrane element designed for brackish water treatment.

RO
Kovalus logo

Product profile

TFC 9822 HR-400

Koch Membrane Systems TFC 9822 HR-400 is an 8-inch reverse osmosis element designed for brackish water treatment with proprietary TFC®-HR polyamide membrane.

RO
Kovalus logo

Product profile

TFC 8822 XR-365

The FLUID SYSTEMS® TFC®-XR 8” ELEMENT is an extra high rejection, brackish water reverse osmosis membrane element with proprietary TFC polyamide chemistry.

RO
Kovalus logo

Product profile

TFC 8822 XR-400

This is an extra high rejection, brackish water reverse osmosis membrane element with a proprietary TFC polyamide membrane.

Cellulose Acetate Elements

7 product profiles

RO
Kovalus logo

Product profile

TFC-8040-S-410 8"

This TFC®-S 8” element is a low-pressure RO membrane for municipal water softening and THMFP reduction.

RO
Kovalus logo

Product profile

TFC 8923 S 400/ Softening / Low pressure

The Koch Membrane Systems TFC 8923 S 400 is a reverse osmosis membrane element designed for municipal water softening and trihalomethane formation potential reduction.

RO
Kovalus logo

Product profile

TFC 8933 S 575 Magnum / Softening / Low pressure

This Koch Membrane Systems TFC-S 8" Magnum element is a spiral-wound reverse osmosis membrane designed for softening and low-pressure applications.

RO
Kovalus logo

Product profile

ROGA-4040-HR 4"

ROGA-4040-HR 4" is a reverse-osmosis membrane element for selection by feed type, target water quality, membrane area, and operating pressure.

RO
Kovalus logo

Product profile

ROGA-8040-HR-325 8"

This ROGA-8040-HR-325 is an 8-inch spiral wound reverse osmosis membrane element with a proprietary cellulose acetate membrane chemistry.

UF
Kovalus logo

Product profile

ROGA-8040-UF-325 8"

The Fluid Systems ROGA-UF 8" element is a cellulose acetate ultrafiltration membrane designed for RO pretreatment and water supply applications.

Show remaining Cellulose Acetate Elements profiles (1)
RO
Kovalus logo

Product profile

ROGA-HR8 / ROGA-8040-HR-325 / 8232 HR Magnum

The ROGA-8040-HR-325 is an 8-inch cellulose acetate reverse osmosis membrane element designed for high rejection applications in municipal and industrial water treatment.

Ultrafiltration Cartridges / Hollow Fiber

22 product profiles

UF
Kovalus logo

Product profile

Romicon 1" PM5 Hollow Fiber

The Romicon 1" PM5 Hollow Fiber cartridge is an ultrafiltration element designed for process streams with a 5,000 Dalton molecular weight cutoff, featuring a polysulfone...

UF
Kovalus logo

Product profile

Romicon 3" PM5 Hollow Fiber

The Romicon 3" PM5 Hollow Fiber is a 3-inch diameter ultrafiltration cartridge designed for process streams with a 5,000 Dalton molecular weight cutoff.

UF
Kovalus logo

Product profile

Romicon 5" PM5 Hollow Fiber

The Romicon 5" PM5 is a hollow fiber ultrafiltration cartridge made with polysulfone membrane and housing.

UF
Kovalus logo

Product profile

Romicon 6" PM5 Hollow Fiber

This Romicon 6" PM5 is a hollow fiber cartridge designed for ultrafiltration, featuring a polysulfone membrane and housing construction.

UF
Kovalus logo

Product profile

Romicon HF 5043-66-45-XM50

This industrial hollow fiber ultrafiltration module is designed for wastewater treatment and features an acrylonitrile co-polymer membrane.

UF
Kovalus logo

Product profile

Winefilter II 5043 Hollow Fiber Crossflow

The Winefilter II 5043 is a hollow fiber crossflow cartridge designed for wine filtration applications, featuring a polysulfone membrane and housing.

Show remaining Ultrafiltration Cartridges / Hollow Fiber profiles (16)
UF
Kovalus logo

Product profile

Winefilter II 6060 Hollow Fiber Crossflow

The Winefilter II 6060 is a 6-inch hollow fiber crossflow cartridge designed for wine filtration.

UF
Kovalus logo

Product profile

Winefilter II MF 5043 Hollow Fiber Crossflow

The Winefilter II MF 5043 is a hollow fiber microfiltration cartridge designed for wine filtration.

UF
Kovalus logo

Product profile

Winefilter II MF 6043 Hollow Fiber Crossflow

The Winefilter II MF 6043 is a hollow fiber crossflow microfiltration cartridge designed for wine filtration.

UF
Kovalus logo

Product profile

Super G Plus Module HFM 500

This Koch Membrane Systems Super G Plus Module HFM 500 is an ultrafiltration multitube module designed for juice processing.

UF
Kovalus logo

Product profile

ABCOR INDUCOR 12 HFM 251 ICV

The ABCOR INDUCOR 12 HFM 251 ICV is a reverse osmosis and nanofiltration membrane element with a PVDF neutral charge membrane.

UF
Kovalus logo

Product profile

ABCOR INDUCOR 10 HFM 251 ICV

Product Name:ABCOR® - INDUCORTM-G MODULE: 10-HFM-251-ICV、Module Type:Industrial Multitubular Ultrafiltration Module、Part Number (KPN):0712501、Membrane...

UF
Kovalus logo

Product profile

Romipro 1" 1018-1.0-43-PM10 Hollow Fiber

The Romipro 1" 1018-1.0-43-PM10 is a hollow fiber ultrafiltration cartridge designed for pharmaceutical applications with a polysulfone membrane and housing.

UF
Kovalus logo

Product profile

Spirapro HFK 4333-K131-VSV Pharmaceutical

The Spirapro HFK 4333-K131-VSV is a pharmaceutical-grade ultrafiltration element featuring a proprietary polyethersulfone membrane with a 10,000 Dalton separation range.

UF
Kovalus logo

Product profile

Targa 8072-742-20-PM10 Hollow Fiber

The Targa 8072-742-20-PM10 is an 8-inch industrial hollow fiber cartridge for ultrafiltration applications.

UF
Kovalus logo

Product profile

Targa 8048-238-43-PM100 Hollow Fiber

The Targa 8048-238-43-PM100 is an 8-inch industrial ultrafiltration hollow fiber cartridge with a proprietary polysulfone membrane chemistry and 100,000 nominal molecular...

UF
Kovalus logo

Product profile

Targa II 8048-35 Hollow Fiber

The Targa II 8048-35 is an 8-inch hollow fiber cartridge for water ultrafiltration.

UF
Kovalus logo

Product profile

Targa II 10048-35 Hollow Fiber

The Targa II 10048-35 is a 10-inch hollow fiber ultrafiltration cartridge with a proprietary semi-permeable polyethersulfone membrane.

UF
Kovalus logo

Product profile

Targa 8072-367-43-PM10 Hollow Fiber

The TARGA™ PM10 Hollow Fiber Cartridge is an 8-inch industrial ultrafiltration cartridge featuring a proprietary polysulfone membrane with a nominal MWCO of 10,000.

UF
Kovalus logo

Product profile

SUPER COR XL 3012 HFM 180

The SUPER COR XL 3012 HFM 180 is an ultrafiltration multitube module designed for juice processing applications.

UF
Kovalus logo

Product profile

SUPER COR XL PLUS 4312 MFK 180

This Koch Membrane Systems ULTRAFILTRATION MODULE is designed for juice processing applications.

UF
Kovalus logo

Product profile

SUPER COR XL 3010 HFM 180

This Koch Membrane Systems SUPER COR XL 3010 HFM 180 is an ultrafiltration module utilizing PVDF membranes for juice processing.

Microfiltration

19 product profiles

NF
Kovalus logo

Product profile

SelRO 8040 MPS-34-NYHN

This Koch Membrane Systems SelRO 8040 MPS-34-NYHN is a spiral wound nanofiltration element with a 200 Dalton MWCO, ideal for acid and caustic recovery.

NF
Kovalus logo

Product profile

SelRO MPS-34 2540 A2X

The SelRO MPS-34 is a pH-stable nanofiltration membrane element with a 200 Dalton molecular weight cut-off, suitable for acid and caustic recovery.

NF
Kovalus logo

Product profile

SelRO MPS-34-8040-B2X

This SelRO MPS-34-8040-B2X is a pH stable nanofiltration membrane element with a 200 Dalton molecular weight cut-off for acid and caustic recovery applications.

NF
Kovalus logo

Product profile

SelRO 8038 MPS-34-ZYT

This is an 8-inch spiral wound nanofiltration membrane element with a proprietary composite membrane and a molecular weight cut-off of 200 Daltons.

NF
Kovalus logo

Product profile

SelRO 8040 MPS-36-NYHN

This SelRO 8040 MPS-36-NYHN is a nanofiltration spiral element with a proprietary composite membrane chemistry, designed for applications like acid and caustic recovery.

NF
Kovalus logo

Product profile

SelRO 3838 MPS-36-VYV

The SelRO 3838 MPS-36-VYV is a 4-inch acid and caustic stable nanofiltration membrane element for product concentration and purification.

Show remaining Microfiltration profiles (13)
NF
Kovalus logo

Product profile

Dairy-Pro 3838 NF-200-30

The Dairy-Pro NF-200 element is a sanitary spiral wound nanofiltration membrane for desalting and separation of proteins, sugars, and carbohydrates.

NF
Kovalus logo

Product profile

Spirapro 3838 SR3-NYV Pharmaceutical

The Spirapro 3838 SR3-NYV is a sanitary spiral wound nanofiltration membrane element with a proprietary TFC polyamide chemistry for desalting and separation of...

NF
Kovalus logo

Product profile

Spirapro 8040 SR3-NYVP Pharmaceutical

This sanitary spiral wound nanofiltration element uses a proprietary TFC polyamide membrane with a 200 dalton molecular weight cut-off for desalting, concentration, and...

RO Membranes
Kovalus logo

Product profile

Dairy-Pro 3838 MF-0.1-45

The Dairy-Pro 3838 MF-0.1-45 is a microfiltration spiral wound sanitary element with a proprietary PES membrane for applications like whey de-fatting and casein...

RO Membranes
Kovalus logo

Product profile

3838 MFK-601

This Koch Membrane Systems MFK™ FOOD & DAIRY MF ELEMENT is a 3.8-inch diameter microfiltration spiral element with a 0.4-micron separation range.

RO Membranes
Kovalus logo

Product profile

8338-MFK-601

This Koch Membrane Systems MFK™ Food & Dairy microfiltration element features a proprietary polyethersulfone (PES) membrane with a 0.4-micron separation range.

RO Membranes
Kovalus logo

Product profile

8838 MFK-601

The 8838 MFK-601 is a microfiltration spiral-wound element from Koch Membrane Systems with a proprietary polyethersulfone membrane layer for food and dairy applications.

RO Membranes
Kovalus logo

Product profile

3838 MFK-603-FYV

The 3838 MFK-603-FYV is a sanitary microfiltration element with a 0.1 micron separation range, constructed from proprietary polyethersulfone (PES) membrane.

RO Membranes
Kovalus logo

Product profile

8338-MFK-603-FYT

The 8338-MFK-603-FYT is a sanitary spiral wound microfiltration membrane element with a proprietary polyethersulfone (PES) layer for food and dairy applications.

RO Membranes
Kovalus logo

Product profile

3838 MFK-618

The 3838 MFK-618 is a 4-inch microfiltration element with a proprietary semi-permeable polyethersulfone (PES) membrane offering 0.1 micron separation.

RO Membranes
Kovalus logo

Product profile

SUPER-COR 3010-MFK-617

The SUPER-COR 3010-MFK-617 is a microfiltration module featuring a polyethersulfone membrane with a nominal pore size of 0.1 micron.

RO Membranes
Kovalus logo

Product profile

SUPER-COR XL 3012-MFK-617

This is a Koch Membrane Systems SUPER-COR XL microfiltration module designed for juice processing with a 0.1 micron polyethersulfone membrane.

RO Membranes
Kovalus logo

Product profile

SUPER-COR XL PLUS 4312-MFK-6

The SUPER-COR XL PLUS 4312-MFK-6 is a microfiltration membrane module designed for juice processing.

Food & Dairy UF / NF RO Elements

7 product profiles

NF
Kovalus logo

Product profile

Dairy-NF 3838 SR3D-NYV

This Koch Membrane Systems SR3D sanitary nanofiltration element is designed for desalting and separation of proteins, sugars, and carbohydrates.

NF
Kovalus logo

Product profile

Dairy-UF 3838 HFK-131

The Dairy-UF 3838 HFK-131 is a sanitary spiral wound ultrafiltration membrane element with a proprietary polyethersulfone layer and a 10,000 Dalton separation range.

NF
Kovalus logo

Product profile

POLISHING RO ELEMENT 8040 HRX-NYVP

This Koch Membrane Systems 8040 HRX-NYVP is a high rejection reverse osmosis sanitary element designed for food and dairy polishing applications.

NF
Kovalus logo

Product profile

Dairy-MF 3838 MFK-618-NYV

This sanitary spiral wound microfiltration element is designed for food and dairy applications, featuring a proprietary polyethersulfone membrane.

NF
Kovalus logo

Product profile

Dairy-MF 3838 MFK-603-FYV

This sanitary spiral wound membrane element utilizes a proprietary polyethersulfone (PES) MFK™-603 membrane with 0.1 micron separation for RO and NF applications.

NF
Kovalus logo

Product profile

Dairy-Pro 3838 RO - 30

The Dairy-Pro 3838 RO - 30 is a sanitary spiral wound reverse osmosis membrane element designed for dairy processing applications like whey concentration.

Show remaining Food & Dairy UF / NF RO Elements profiles (1)
NF
Kovalus logo

Product profile

Dairy-UF XL 3838 HFK-131-NYV

Koch Membrane Systems XL-1000 FOOD & DAIRY UF ELEMENTS are ultrafiltration (UF) spiral elements available in 4”, 6”, and 8” diameters, featuring patented Fused-Fold...

Ultrafiltration

19 product profiles

UF
Kovalus logo

Product profile

Dairy-UF 3838 HFM-180-VYV

This is a sanitary ultrafiltration spiral element with a proprietary PVDF membrane chemistry and a separation range of 100,000 daltons.

UF
Kovalus logo

Product profile

Spiral UF 7533-M183-VPF

This Koch Membrane Systems Spiral Ultrafiltration Element is designed for cathodic electrocoat paint applications with a positive charge PVDF membrane.

UF
Kovalus logo

Product profile

Dairy-UF HpHT 3838-K131-NYV

This is a Koch Membrane Systems HpHT HFK-131 ultrafiltration spiral wound element with a proprietary polyethersulfone membrane.

UF
Kovalus logo

Product profile

Dairy-Pro 6338 UF 5K/10K

The Koch Membrane Systems Dairy-Pro™ UF elements are sanitary spiral wound ultrafiltration membranes with proprietary polyethersulfone layers.

UF
Kovalus logo

Product profile

ABCOR FEG PLUS 10-HFM-251-PVI

The ABCOR FEG PLUS 10-HFM-251-PVI is a tubular ultrafiltration module with a PVDF membrane, designed for industrial applications.

UF
Kovalus logo

Product profile

Spirapak 4033-HFM-183-LPP

This Spirapak 4033-HFM-183-LPP is a spiral ultrafiltration module designed for cathodic electrocoat paint applications.

Show remaining Ultrafiltration profiles (13)
UF
Kovalus logo

Product profile

Spirapak 4033-HFM-183-VPP

This Koch Membrane Systems SPIRAPAK™ module is a spiral ultrafiltration unit designed for cathodic electrocoat paint applications.

UF
Kovalus logo

Product profile

Spirapak 4033-HFM-300-VPP

This Spirapak module is a spiral wound ultrafiltration membrane element with a PVDF HFM membrane chemistry and an integrated PVC housing.

UF
Kovalus logo

Product profile

Spirapak 4038-HFM-183-LPP3

This Spirapak 4038-HFM-183-LPP3 is a spiral ultrafiltration module with a positively charged PVDF membrane designed for cathodic electrocoat paint applications.

UF
Kovalus logo

Product profile

Spirapak 4038-HFM-183-VPP3

This Koch Membrane Systems Spirapak module is a spiral ultrafiltration element designed for cathodic electrocoat paint applications.

UF
Kovalus logo

Product profile

3838 HFK-328

This Koch Membrane Systems HFK-328 is an ultrafiltration element with a proprietary polyethersulfone membrane, capable of separating molecules with a molecular weight of...

UF
Kovalus logo

Product profile

Kpak 8638-M-183-LPP

This PVDF spiral wound ultrafiltration module has a membrane area of 288 ft² and is designed for use with reverse osmosis and nanofiltration systems.

UF
Kovalus logo

Product profile

Kpak 8638-M-183-VPP

This Kpak 8638-M-183-VPP is an 8-inch spiral wound membrane element with PVDF HFM membrane chemistry for ultrafiltration applications.

UF
Kovalus logo

Product profile

Kpak 8638-M-300-LPP

This Kpak 8638-M-300-LPP is a spiral wound reverse osmosis/nanofiltration membrane element with PVDF HFM chemistry and an integrated PVC housing.

UF
Kovalus logo

Product profile

Kpak 10738-M-183-LPP

This is a Koch Membrane Systems Kpak 10738-M-183-LPP Zero Bypass E-Coat Ultrafiltration Spiral Module with a PVDF HFM membrane and 462 ft² of area.

UF
Kovalus logo

Product profile

Kpak 10738-M-300-LPP

This is a Kpak 10738-M-300-LPP Zero Bypass E-Coat Ultrafiltration Spiral Module with PVDF HFM membrane chemistry.

UF
Kovalus logo

Product profile

HpHT 3838-K131-NYV

This is a Koch Membrane Systems HpHT membrane element designed for high-temperature and high-pressure reverse osmosis and nanofiltration applications.

UF
Kovalus logo

Product profile

3838 HFM 180

The 3838 HFM 180 is a reverse osmosis membrane element designed for food and dairy applications.

UF
Kovalus logo

Product profile

7533-M183-VPF

This is a Koch Membrane Systems Fluid Systems™ spiral wound membrane element designed for reverse osmosis and nanofiltration applications.

Hollow Fiber Modules / MBR Applications

7 product profiles

RO Membranes
Kovalus logo

Product profile

Pulsion Puron Hollow Fiber Rows

This Pulsion Puron hollow fiber row is a submerged membrane designed for MBR applications, featuring a proprietary PVDF membrane chemistry and polyester fiber support.

RO Membranes
Kovalus logo

Product profile

Pulsion Puron LE 8

The Pulsion Puron LE 8 is a submerged hollow fiber membrane module designed for MBR applications, featuring a proprietary PVDF braided hollow fiber.

RO Membranes
Kovalus logo

Product profile

Puron PSH 250

The Puron PSH 250 is a hollow fiber submerged membrane module designed for MBR applications, featuring a proprietary PVDF membrane chemistry.

RO Membranes
Kovalus logo

Product profile

Puron PSH 31HD

The Puron PSH 31HD is a hollow fiber submerged membrane row designed for MBR applications, featuring a proprietary PVDF membrane chemistry.

RO Membranes
Kovalus logo

Product profile

Puron PSH 95

The Puron PSH 95 is a submerged hollow fiber membrane module for MBR applications featuring a proprietary PVDF membrane with a nominal pore size of 0.03 µm.

RO Membranes
Kovalus logo

Product profile

Puron PSH 330

The Puron PSH 330 is a submerged hollow fiber membrane module designed for MBR applications, featuring a proprietary PVDF membrane chemistry.

Show remaining Hollow Fiber Modules / MBR Applications profiles (1)
RO Membranes
Kovalus logo

Product profile

Puron PHF 480

The Puron PHF 480 is a hollow fiber submerged membrane module utilizing proprietary PVDF for water and wastewater treatment.

Surface Water

4 product profiles

RO
Kovalus logo

Product profile

KMS 3838 HRX-NYV

The KMS 3838 HRX-NYV is a high rejection reverse osmosis membrane element with proprietary TFC® polyamide chemistry.

RO
Kovalus logo

Product profile

TFC-FR8 / TFC 8822 FR-365

Koch Membrane Systems TFC® - FR 8-inch series elements are fouling-resistant, low-pressure brackish reverse osmosis membranes designed for surface water and wastewater...

RO
Kovalus logo

Product profile

TFC-FR8 / TFC 8822 FR-400

The TFC-FR8 / TFC 8822 FR-400 is a fouling-resistant, low-pressure reverse osmosis membrane element for brackish surface water or wastewater treatment.

RO
Kovalus logo

Product profile

TFC-FR8 / TFC 8832 FR-575 Magnum

The TFC-FR8 / TFC 8832 FR-575 Magnum is a fouling-resistant reverse osmosis membrane element designed for surface water and wastewater treatment.

Sanitairy UF Elements

2 product profiles

UF
Kovalus logo

Product profile

HpHT 3838 UF K328/K131 - 30

The HpHT 3838 UF K328/K131 is a sanitary ultrafiltration element with a proprietary semi-permeable polyethersulfone membrane.

UF
Kovalus logo

Product profile

Dairy-Pro HpHT 3838 UF 5K/10K - 80

The Dairy-Pro HpHT UF 5K/10K is a sanitary ultrafiltration spiral wound element designed for dairy processing with a proprietary polyethersulfone membrane.

Polishing Water

4 product profiles

RO
Kovalus logo

Product profile

8823 ULP-400

This Koch Membrane Systems (Fluid Systems™) 8823 ULP-400 is an ultra-low pressure reverse osmosis membrane element for potable water production.

RO
Kovalus logo

Product profile

TFC 4040-ULP

This ultra-low pressure reverse osmosis element uses a proprietary TFC polyamide membrane for light industrial and potable water production.

RO
Kovalus logo

Product profile

TFC 4040-ULP-T

The FLUID SYSTEMS® TFC®- ULP® 4” ELEMENT is an ultra-low pressure reverse osmosis (RO) element.

RO
Kovalus logo

Product profile

3838 HR-NYV

This reverse osmosis element is designed for sanitary food and dairy applications with proprietary TFC® polyamide membrane chemistry.

Overview Koch Membranes

1 product profiles

NF
Kovalus logo

Product profile

Spiral Wound Cataloque

This product is a range of spiral-wound membrane elements from Koch Membrane Systems for reverse osmosis and nanofiltration applications.

Koch Membrane Systems / Fluid Systems™ RO Membranes | Models & Datasheets | AquaChain Guide