Datasheet summary
S085 HF 4040
Engineering summary from PDF text extraction for S085 HF 4040. Verify every value with the OEM datasheet.
Summary
Product identification
The LEWABRANE® RO S085 HF 4040 elements are spiral-wound, composite polyamide membrane elements designed for seawater desalination. The S085 HF membrane features an extremely durable, highly cross-linked polymeric separating layer suitable for high salinity, high-pressure applications. These elements are recommended for single-pass and two-pass applications where stable salt rejection performance is a key consideration.
General Information
- Feed spacer thickness: 0.8 mm (31 mil)
- Membrane area: 7.9 m² (85 ft²)
- Salt rejection, average: 99.8 %
- Salt rejection, minimum: 99.5 %
- Boron rejection, typical: 92.0 %
- Permeate flow rate, average: 7.2 m³/d (1910 gpd)
- Permeate flow rate, minimum: 5.8 m³/d (1530 gpd)
Elements are tested under the following conditions: applied pressure 55.2 bar (800 psi), NaCl concentration 32,000 mg/l (or when tested on a mixed solution of 32,000 mg/l NaCl and 5 mg/l Boron), operating temperature 25 °C (77 °F), pH 8, and recovery rate 8 %.
Operating limits
- Operating pressure, maximum: 83 bar (1200 psi)
- Operating temperature, maximum: 45 °C (113 °F)
- pH range during operating: 2 - 11
- pH range during cleaning: 1 - 12
- Pressure drop per element, maximum: 1.0 bar (15 psi)
- Pressure drop per vessel, maximum: 3.5 bar (50 psi)
- Chlorine concentration, maximum: 0.1 ppm
Feed water
- Feed water SDI, maximum: 5
- Chlorine concentration, maximum: 0.1 ppm
Product water
- Salt rejection, average: 99.8 %
- Salt rejection, minimum: 99.5 %
- Boron rejection, typical: 92.0 %
Mechanical / hydraulic
Element Dimensions:
-
A (Length): 1016 mm (40 inch)
-
B (Diameter): 100 mm (3.9 inch)
-
C (OD): 19 mm (0.75 inch)
-
D (Length): 26 mm (1.05 inch)
-
Operating pressure, maximum: 83 bar (1200 psi)
-
Pressure drop per element, maximum: 1.0 bar (15 psi)
-
Pressure drop per vessel, maximum: 3.5 bar (50 psi)
Additional Information
- Treat RO Elements with care; do not drop.
- Each RO Element is wet tested, preserved in a 1% weight sodium bisulfite solution, and vacuum packed in oxygen barrier bags.
- During storage, avoid freezing and direct sunlight. The temperature should be below 35 °C (95 °F).
- After installation, keep the RO Elements wet, and use a compatible preservative for storage duration longer than 7 days.
- During initial start-up, discharge the first permeate to drain for 30 minutes.
- Permeate back pressure should not exceed feed pressure at any time.
- The RO Elements shall be maintained in a clean condition, unfouled by particulate matter or precipitates or biological growth.
- Consider cleaning, if the pressure drop increases by 20% or water permeability decreases by 10%.
- Use only chemicals which are compatible with the membrane.