S085 HR 4040

Engineering summary from PDF text extraction for S085 HR 4040. Verify every value with the OEM datasheet.

Summary

Product identification

Lewabrane® RO S085 HR 4040 elements are spiral-wound, composite polyamide membrane elements designed for the desalination of seawater. The S085 HR membrane features an extremely durable, highly cross-linked polymeric separating layer suitable for high salinity, high pressure applications. It is recommended for single pass applications where stable salt rejection performance is an important consideration.

  • Edition: 2014-05-23
  • Feed spacer thickness: 0.8 mm (31 mil)
  • Membrane area: 7.9 m² (85 ft²)

Product water

  • Salt rejection, average: 99.8 %
  • Salt rejection, minimum: 99.5 %
  • Boron rejection, typical: 93.0 %
  • Permeate flow rate, average: 5.2 m³/d (1380 gpd)
  • Permeate flow rate, minimum: 4.2 m³/d (1100 gpd)

Performance Test Conditions: Elements are tested under the following conditions:

  • Applied pressure: 55.2 bar (800 psi)
  • NaCl concentration: 32,000 mg/L (or when tested on a mixed solution of 32,000 mg/L NaCl and 5 mg/L Boron)
  • Operating temperature: 25 °C (77 °F)
  • pH: 8
  • Recovery rate: 8 %

Operating limits

  • Operating pressure, maximum: 83 bar (1200 psi)
  • Operating temperature, maximum: 45 °C (113 °F)
  • pH range during operating: 2 - 11
  • pH range during cleaning: 1 - 12
  • Pressure drop per element, maximum: 1.0 bar (15 psi)
  • Pressure drop per vessel, maximum: 3.5 bar (50 psi)

Feed water

  • SDI, maximum: 5
  • Feed flow, maximum: 4.0 m³/h (18 gpm)
  • Concentrate flow, minimum: 0.6 m³/h (3 gpm)
  • Chlorine concentration, maximum: 0.1 ppm

Mechanical / hydraulic

  • Element Dimensions:
    • A (Length): 1016 mm (40 inch)
    • B (Diameter): 100 mm (4.0 inch)
    • C (OD): 19 mm (0.75 inch)
    • D (Length): 26 mm (1.05 inch)

General Care and Maintenance

  • Treat RO elements with care; do not drop the element.
  • Each RO element is wet tested, preserved in a 1% weight sodium bisulfite solution, and vacuum packed in oxygen barrier bags.
  • During storage, avoid freezing and direct sunlight. The temperature should be below 35 °C (95 °F).
  • After installation, keep the RO elements wet, and use a compatible preservative for storage durations longer than 7 days.
  • During the initial start-up, discharge the first permeate to drain for 30 minutes.
  • Permeate back pressure should not exceed feed pressure at any time.
  • Consider cleaning if the pressure drop increases by 20% or water permeability decreases by 10%.
  • Use only chemicals which are compatible with the membrane.