Datasheet summary
S440 HR
Engineering summary from PDF text extraction for S440 HR. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: LEWABRANE® RO S440 HR
- Type: Spiral-wound, composite polyamide membrane elements.
- Application: Designed for the desalination of seawater; suitable for high salinity, high pressure applications. Recommended for single pass applications where stable salt rejection performance is an important consideration.
- Membrane: Characterized by an extremely durable, highly cross-linked polymeric separating layer.
- Edition: 2016-09-01
Performance Specifications
- Membrane area: 40.9 m² (440 ft²)
- Salt rejection, average: 99.8 %
- Salt rejection, minimum: 99.5 %
- Boron rejection, typical: 93.0 %
- Permeate flow rate, average: 27.3 m³/d (7200 gpd)
- Permeate flow rate, minimum: 21.8 m³/d (5760 gpd)
- Element is tested under the following conditions:
- Applied pressure: 55.2 bar (800 psi)
- NaCl concentration: 32,000 mg/l (or when tested on a mixed solution of 32,000 mg/l NaCl and 5 mg/l Boron)
- Operating temperature: 25 °C (77 °F)
- pH: 8
- Recovery rate: 8 %
Operating limits
- Operating pressure, maximum: 83 bar (1200 psi)
- Operating temperature, maximum: 45 °C (113 °F)
- Feed water SDI, maximum: 5
- pH range during operating: 2 - 11
- pH range during cleaning: 1 - 12
- Chlorine concentration, maximum: 0.1 ppm
Mechanical / Hydraulic
- Feed spacer thickness: 0.7 mm (28 mil)
- Pressure drop per element, maximum: 1.0 bar (15 psi)
- Pressure drop per vessel, maximum: 3.5 bar (50 psi)
- Element Dimensions:
- Length (A): 1016 mm (40 inch)
- Diameter (B): 201 mm (7.9 inch)
- ID (C): 29 mm (1.125 inch)
Handling and Storage
- Treat RO Elements with care; do not drop the element.
- Each RO Element is wet tested, preserved in a 1% weight sodium bisulfite solution, and vacuum packed in oxygen barrier bags.
- During storage, avoid freezing and direct sunlight. The temperature should be below 35 °C (95 °F).
- After Installation:
- Keep the RO Elements wet, and use a compatible preservative for storage duration longer than 7 days.
- During the initial start-up, discharge the first permeate to drain for 30 min.
- Permeate back pressure should not exceed feed pressure at any time.
- The RO Elements shall be maintained in a clean condition, unfouled by particulate matter or precipitates or biological growth.
- Consider cleaning, if the pressure drop increases by 20% or water permeability decreases by 10%.
- Use only chemicals which are compatible with the membrane.