Back to LG RO Elements
LG logo

Datasheet summary

LG BW 400 AFR G2

Engineering summary from PDF text extraction for LG BW 400 AFR G2. Verify every value with the OEM datasheet.

Summary

Product identification

LG BW 400 AFR G2 brackish water reverse osmosis (RO) membranes are designed for municipal and industrial applications. These elements incorporate innovative Thin Film Nanocomposite (TFN) technology, providing superior performance with intrinsic anti-fouling properties. They are described as anti-fouling, high rejection, high flow, and high durability, equipped with fouling tolerant low differential pressure (dP) spacer technology.

The LG BW 400 AFR G2 offers enhanced fouling resistance, high rejection, flow, and durability, aiming to reduce total cost of ownership. They are suitable for high salinity brackish water and wastewater reuse applications with challenging feed water, utilizing state-of-the-art feed spacer technology to reduce differential pressure and cleaning frequency.

Product Specifications

  • Active Membrane Area: 400 ft² (37 m²)
  • Permeate flow rate: 11,500 GPD (43.5 m³/d)
  • Stabilized Salt Rejection: 99.7%
  • Minimum Salt Rejection: 99.6%
  • Feed Spacer: 34 mil, low dP

Test Conditions:

  • 2,000 ppm NaCl at 25°C (77°F)
  • 225 psi (15.5 bar)
  • pH 7
  • Recovery 15%
  • Permeate flows for individual elements may vary +/-15%.

Operating limits

  • Max. Applied pressure: 600 psi (41 bar)
  • Max. Chlorine concentration: < 0.1 ppm
  • Max. Operating temperature: 45°C (113°F)
  • pH Range, Continuous (Cleaning): 2-11 (1-13)
  • Max. Feedwater turbidity: 1.0 NTU
  • Max. Feedwater SDI (15 mins): 5.0
  • Max. Feed flow: 75 gpm (17 m³/h)
  • Max. Pressure drop (ΔP) for each element: 15 psi (1.0 bar)

Mechanical / hydraulic

  • A: 1,016 mm (40 in.)
  • B: 200 mm (7.9 in.)
  • C: 28.6 mm (1.125 in.)
  • Weight: 16 kg (35 lbs.)

All dimensional information is indicative and for reference purposes only.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.