Datasheet summary
LG BW 440 UES
Engineering summary from PDF text extraction for LG BW 440 UES. Verify every value with the OEM datasheet.
Summary
Product identification
LG Chem’s NanoH₂O™ LG BW 440 UES are Ultra Low Energy brackish water reverse osmosis (RO) membranes. They incorporate innovative Thin Film Nanocomposite (TFN) technology, offering superior performance with intrinsic anti-fouling properties. These membranes are suitable for low salinity brackish water applications, providing high permeability at ultra-low feed pressure to reduce operating costs.
Product specifications
- Active Membrane Area: 440 ft² (41 m²)
- Permeate flow rate: 12,650 GPD (47.9 m³/d)
- Stabilized Salt Rejection: 99.0%
- Minimum Salt Rejection: 98.0%
- Feed Spacer: 28 mil
Test Conditions: 2,000 ppm NaCl at 25°C (77°F), 125 psi (8.6 bar), pH 7, Recovery 15%. Permeate flows for individual elements may vary +/-20%.
Operating limits
- Max. Applied pressure: 600 psi (41 bar)
- Max. Chlorine concentration: < 0.1 ppm
- Max. Operating temperature: 45°C (113°F)
- pH Range, Continuous: 2-11
- pH Range, Cleaning: 2-12
- Max. Feedwater turbidity: 1.0 NTU
- Max. Feedwater SDI (15 mins): 5.0
- Max. Feed flow: 75 gpm (17 m³/h)
- Max. Pressure drop (ΔP) for each element: 15 psi (1.0 bar)
Mechanical / hydraulic
- A: 1,016 mm (40 in.)
- B: 200 mm (7.9 in.)
- C: 28.6 mm (1.125 in.)
- Weight: 16 kg (35 lbs.)
All dimensional information is indicative and for reference purposes only.
Referential performance at 500 ppm NaCl
- At 100 psi (6.89 bar): 12,430 GPD, 99.3% rejection
- At 110 psi (7.58 bar): 13,750 GPD, 99.4% rejection
Test Conditions: 100/110 psi, 500 ppm NaCl at 25°C (77°F), pH 7, Recovery 15%. All calculated data is obtained from Q+ software.
Disclaimer: This summary is based on the provided text extract. The extraction process may miss figures, footnotes, or the latest revisions. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)