LG SW 440 SR G2

Engineering summary from PDF text extraction for LG SW 440 SR G2. Verify every value with the OEM datasheet.

Summary

Product identification

LG SW 440 SR G2 is a seawater reverse osmosis (RO) membrane. These LG SW G2 membranes utilize enhanced Thin Film Nanocomposite (TFN) technology, suitable for high salinity seawater applications.

Key benefits of LG SW G2 membranes include:

  • Improved permeate quality without increasing operating pressure
  • Reduced energy cost without sacrificing the permeate quality
  • Reduced capital and operation costs for multi-pass SWRO systems

Product specifications

  • Active Membrane Area: 440 ft² (41 m²)
  • Permeate Flow Rate: 6,600 GPD (25.0 m³/d)
  • Stabilized Salt Rejection: 99.89 %
  • Minimum Salt Rejection: 99.75 %
  • Boron Rejection: 93 %
  • Feed Spacer: 28 mil

Test Conditions: 32,000 ppm NaCl, 5 ppm boron at 25°C (77°F), 800 psi (55 bar), pH 8, Recovery 8%. Permeate flows for individual elements may vary +/-15%.

Operating limits

  • Max. Applied pressure: 1,200 psi (82.7 bar)
  • Max. Chlorine concentration: < 0.1 ppm
  • Max. Operating temperature: 45°C (113°F)
  • pH Range, Continuous (Cleaning): 2-11 (2-13)
  • Max. Feedwater turbidity: 1.0 NTU
  • Max. Feedwater SDI (15 mins): 5.0
  • Max. Feed flow: 75 gpm (17 m³/h)
  • Min. Ratio of concentrate to permeate flow for any element: 5 : 1
  • Max. Pressure drop (ΔP) for each element: 15 psi (1.0 bar)

Mechanical / hydraulic

  • A: 1,016 mm (40 in.)
  • B: 200 mm (7.9 in.)
  • C: 28.6 mm (1.125 in.)
  • Weight: 16 kg (35 lbs.)

All dimensional information is indicative and for reference purpose only.