Back to Membranium
RM Nanotech logo

Datasheet summary

K 8040-C

Engineering summary from PDF text extraction for K 8040-C. Verify every value with the OEM datasheet.

Summary

Product identification

The Membranium K Series consists of spiral wound nanoRO reverse osmosis membrane elements, specifically designed for brackish water desalination.

  • Membrane material: Composite polyamide

Operating limits

  • Recommended operation pressure: 1.2-2.0 MPa
  • Maximum operation pressure: 4.1 MPa
  • Maximum pressure drop: 0.07 MPa
  • Operation temperature: 4-45 °С
  • pH at continuous operation (T<35°С): 2-11
  • pH at continuous operation (T<45°С): 3-10.5
  • Chemical cleaning temperature: Not specified precisely, but CIP pH limits vary with temperature.
  • CIP pH (short time operation):
    • 2-11 (at T<45 °С)
    • 1-11.5 (at T<35 °С)
    • 1-12 (at T<25 °С)
  • Free chlorine content (max): 0.1 mg/l
  • Maximum feed flow: 17 m³/hr
  • Concentrate/permeate ratio on each element (min): 5:1

Feed water

  • SDI (15 minutes test, max): 5
  • Turbidity (max): 1 NTU

Product water

The nominal rejection is reached after 48 hours of continuous operation on test solution. Minimal rejection refers to a new element after 20 minutes’ test on test solution. Test conditions: NaCl 1500 mg/l, P=1.55 MPa, T=25 °С, pH=7.5. Recovery -15%. Flow of each single element in a batch may vary for +25% / -15%.

ModelFlow (m³/hr)Flow (GPD)Rejection (normal/minimal)Area (m²)Area (ft²)Spacer (mm)Spacer (mil)
К 8040-C1.751100099.5/99.1394200.7128
К 8040-С21.651050099.5/99.1374000.7931
К 8040-С31.55990099.5/99.1353750.8634
К 8040-С-DRY1.751100099.5/99.0394200.7128
К 8040-С2-DRY1.651050099.5/99.0374000.7931
К 8040-С3-DRY1.55990099.5/99.0353750.8634

Mechanical / hydraulic

During continuous work with pH over 10, the temperature must not exceed 35 °С. Each element is supplied with an interconnector.

ModelA (mm)B (mm)B’ (ATD) (mm)C (mm)Weight (kg)
К 8040 –С (2, 3)101620320028.615.5
К 8040 –С-DRY (2, 3)101620320028.614.7