Summary

Product identification

This document describes reverse osmosis membrane elements from the Membranium КM Series, designed for seawater desalination.

  • Membrane material: Composite polyamide (ORM45К)
  • Membrane type: nanoRO
  • Design: Spiral wound
  • Model: КМ 2540-С

Product water

Performance specifications are based on a test solution of 32 g/l NaCl, 5.5 MPa pressure, 25 °С temperature, pH 7.5, and 8% recovery.

  • Nominal Flow: 120 l/hr (750 GPD)
    • Note: Flow of each single element in a batch may vary for +/-20%.
  • Normal Rejection: 99.75%
    • Note: Nominal rejection is reached after 100 hours of continuous operation on test solution.
  • Minimal Rejection: 99.4%
    • Note: Minimal rejection of a new element after 20 minutes' test on test solution.
  • Membrane Area: 2.6 m² (28 ft²)
  • Spacer Thickness: 0.71 mm (28 mil)

Operating limits

  • Recommended Operation Pressure: 4.5-6.5 MPa
  • Maximum Operation Pressure: 7 MPa
  • Maximum Pressure Drop: 0.1 MPa
  • Operation Temperature: 4-45 °С
    • Note: During continuous work with pH over 10, the temperature must not exceed 35 °С.
  • pH Range at Operation: 2-11
    • Note: See temperature note above regarding pH over 10.
  • CIP pH (short time operation): 1-12
  • Free Chlorine Content (max): 0.1 mg/l
  • Maximum Feed Flow: 1.4 m³/hr
  • Concentrate/Permeate Ratio (on each element, min): 5:1
  • SDI (15 minutes test, max): 5
  • Turbidity (max): 1 NTU

Mechanical / hydraulic

  • Model: КМ 2540-С
  • Length (A): 1016 mm
  • Diameter (B): 63.5 mm
  • ATD Diameter (B’): 61 mm
  • Interconnector Diameter (C): 19.1 mm
  • Brine Tube Diameter (D): 30.5 mm
  • Weight: 2.2 kg
  • Construction: Fiberglass Shell
  • Included: Brine Seal, Interconnector supplied with each element.