Back to Membranium
RM Nanotech logo

Datasheet summary

4040-F

Engineering summary from PDF text extraction for 4040-F. Verify every value with the OEM datasheet.

Summary

Product identification

These are Membranium nanoNF Nanofiltration membrane elements.

  • Membrane material: Polypiperazineamide
  • Membrane type: NaRМ
  • Design: Spiral wound, Shrink film-wrapped (-F)
  • Features: For brackish water softening and clarification

Operating limits

  • Recommended operation pressure: 0,6-2,0 MPa
  • Maximum operation pressure, tape overwrap: 2,1 MPa
  • Maximum pressure drop: 0,1 MPa
  • Operation temperature: 4-45 °С
  • pH at continuous operation at T<35°С: 2-11
  • pH at continuous operation at T<45°С: 3-10,5
  • Chemical cleaning, temperature: 40 °С
  • CIP pH (short time operation):
    • T<45: 2-11
    • T<35: 1-11.5
    • T<25: 1-12
  • Acceptable Hydrogen peroxide concentration during continuous operation: 1 mg/l
  • Acceptable Hydrogen peroxide concentration during disinfection (not longer than 30 min): 1000 mg/l
  • Acceptable free Chlorine concentration during continuous operation: 1 mg/l
  • Acceptable free Chlorine concentration during disinfection (not longer than 30 min): 5 mg/l
  • Maximum feed flow: 3,6 m³/hr
  • Concentrate/permeate ratio on each element, minimum: 5:1

Feed water

  • Turbidity: 1 NTU max

Mechanical / hydraulic

The elements are supplied with an interconnector.

Dimensions

  • Model 4040-F(2,3)
    • A: 1016 mm
    • B: 101,6 mm
    • B' (ATD): 100,3 mm
    • C: 19,1 mm
    • D: 26,7 mm
    • Weight: 3,6 kg
  • Model 4040-F-DRY (2,3)
    • A: 1016 mm
    • B: 101,6 mm
    • B' (ATD): 100,3 mm
    • C: 19,1 mm
    • D: 26,7 mm
    • Weight: 3,1 kg

Specification

Test conditions for values marked with *: test solution of NaCl 500 mg/l, P=0,7 MPa, T=25 °С, pH=7,5, Recovery -15%. Test conditions for values marked with **: test solution of MgSO₄ 2000 mg/l, P=0,7 MPa, T=25 °С, pH=7,5, Recovery -15%. Flow of each single element in a batch may vary for +/-20%.

ModelFlow* (m³/hr)Flow** (m³/hr)Flow* (GPD)Flow** (GPD)Rejection* (%)Rejection** (%)Area (m²)Area (ft²)Spacer (mm)Spacer (mil)
4040-F3202602000160060998860,7128
4040-F22802301800144060997,7830,7931
4040-F32702201700135060997,4800,8634
4040-F-DRY3202602000160060998860,7128
4040-F2-DRY2802301800144060997,7830,7931
4040-F3-DRY2702201700135060997,4800,8634