Summary

Product identification

  • Product Name: AQUADYN® UE1060 Hollow Fiber Module
  • Filtration type: Ultrafiltration
  • Membrane type: Hollow fiber
  • Membrane structure: Double asymmetric
  • Membrane potting: Epoxy
  • Membrane material: PES
  • Housing material: uPVC
  • Fiber arrangement: U-Shape
  • Flow type: Out/In
  • Type of filtration: Dead End
  • Regeneration: Back Flush, Forward Flush, Air Scouring
  • Membrane area: 55 m²/592 ft²
  • Hollow fiber diameter OD/ID: 1.55 mm/0.95 mm
  • Pore size: 0.025 µm
  • Standard preservative: Ethanol + Glycerine

Operating limits

  • Applicable water flux: ≤ 6.6 m³/h (≤ 29.1 gpm)
  • Capacity feed pump: ≤ 13.2 m³/h (≤ 58.1 gpm)
  • Capacity back flush pump: ≤ 13.2 m³/h (≤ 58.1 gpm)
  • Max. transmembrane pressure: 1 bar (14.5 psi)
  • Max. module pressure: 1.2 bar (17.4 psi)
  • Applicable air scour rate: 3 - 10 Nm³/h (1.8 - 5.9s cfm)
  • Air pressure: < 1.2 bar (< 17.4 psi)
  • Temperature range: 5 - 45°C (41 - 113°F)
  • pH range, operation: 2 - 12
  • pH range, cleaning: 1 - 13
  • Max. TSS feed: ≤ 350 mg/L
  • Max. NTU feed: ≤ 300 NTU
  • Note: Operating specifications are dependent on feed water quality and operating conditions.

Mechanical / hydraulic

  • Module diameter: 267 mm/10.5 in
  • Module length: 1737 mm/68.4 in
  • Connectors:
    • Feed port: 2” Victaulic
    • Permeate port: 2” Victaulic
    • Reject port: 2” Victaulic
    • Air inlet port: G1/2”
  • Weight of module at shipping: Approx. 41 kg/90.4 lbs