Summary

Product identification

The MICRODYN-NADIR SPIRA-CEL® modules are designed for Nanofiltration, specifically from the OX-NP-4040 Series.

  • NADIR® membrane type: NP010, NP030
  • Membrane material: PES
  • Outer wrap: Industry hard shell

The OX-NP-4040 Series includes models A, B, and C with the following specific characteristics:

  • Model A (NADIR® membrane type NP010)
    • Spacer type: Diamond
    • Spacer thickness: 30 / 0.8 mil / mm
    • Membrane area: 7.6 m²
  • Model B (NADIR® membrane type NP030)
    • Spacer type: Diamond
    • Spacer thickness: 44 / 1.1 mil / mm
    • Membrane area: 6.3 m²
  • Model C (NADIR® membrane type NP030)
    • Spacer type: Parallel
    • Spacer thickness: 44 / 1.1 mil / mm
    • Membrane area: 6.3 m²

Mechanical / hydraulic

  • Module dimensions:
    • Ø Outside Module: 101.5 mm (+0 / -2 tolerance)
    • Length Module: 1016 mm (+1 / -3 tolerance)
    • Ø Inside Permeate tube: 16.0 mm (± 0.1 tolerance)

Operating limits

Recommended operating conditions

  • Prefiltration:
    • For Model A: ≤ 50 µm
    • For Models B & C: ≤ 75 µm
  • Cross flow (1):
    • For Model A: 4 - 8 m³/h
    • For Models B & C: 6 - 10 m³/h
    • (1) for water at 25 °C
  • Permeate pressure: 0 bar

Allowable operating conditions

  • Feed pressure, max.: 40 bar
  • Retentate pressure, min.: 0.7 bar
  • Transmembrane pressure, max.: 40 bar
  • Permeate pressure, max.: 0.35 bar
  • Pressure loss per module, max. (Δpmax):
    • 5 - 50 °C: 2 bar
    • 50 - 65 °C: 1.3 bar
    • 65 - 80 °C: 0.5 bar
  • Pressure loss per housing, max. at 80 °C: 2 bar
  • Processing temperature: 5 - 80 °C
  • pH range during filtration: 3 - 14
  • pH range during CIP: 2 - 14
  • Disinfection with chlorine (2): 35.000 ppmh
    • (2) at 200 ppm chlorine, 30 - 50 °C and pH > 11 for max. 30 min/day