Summary
Product Identification
The BIO-CEL® XL is described as the world's largest submerged BIO-CEL® MBR module for biological wastewater treatment. It is specifically developed for large-scale applications with a total inflow to the MBR plant greater than 2,000 m³/d of wastewater to be treated.
Material Data
- Housing: Stainless Steel
- Piping: Polyvinyl chloride (PVC)
- Connections: Stainless Steel
- Membrane: Polyether sulfone (PES)
- Drainage: Polyester
- Sealings: EPDM
- Diffusor: PP/PUR
Membrane Specifications
- Membrane surface: 1,920 m²
- Nominal MWCO: 150 kDa
- Pore size: 0.04 µm
Operating Limits
- Permissible particle size in sludge: 2 mm
- Maximum airflow rate (Vn): 665 m³/h (Vn is the volume flow rate at standard conditions according to DIN ISO 2533:1979-12)
- Recommended content suspended solids (SS): 12 g/l (Other concentrations possible; consult MICRODYN-NADIR representative)
- Operating pressure: -30 to -400 mbar
- Maximum backwash pressure: 150 mbar
- Operating temperature: 5 - 40° C
- pH range: 2 - 11
- Chlorine resistance: 500 000 ppmh
Dimensions and Weight
- Length: 2786 mm
- Width: 2106 mm
- Height (membrane- and diffusor unit): 2450 mm
- Required ground clearance: 750 mm
- Dry weight: 1900 kg
Connections
- Aeration: Special flange, Adapter (DIN, ANSI; ...) as required
- Permeate: Special flange, Adapter (DIN, ANSI; ...) as required
Advantages
- Cost efficient
- High flux
- Low energy demand
- Simple installation
- Backwashable
- Reliable in operation
- Fine bubble aeration
- High packing density
- Self-healing membrane laminate
- Mechanically cleanable