Summary

Product identification

This datasheet describes the SPIRA-CEL® GY-UP-4040 Series modules for Ultrafiltration.

Membrane TypeNominal MWCO (kDa)Membrane Material
UP0055PES
UP01010PES
UP02020PES
UP150150PES

Mechanical / hydraulic

  • Module Dimensions:
    • Outside Diameter: 101.5 mm (+0 / -2 mm tolerance)
    • Length: 1016 mm (+1 / -3 mm tolerance)
    • Permeate Tube Inside Diameter: 16.0 mm (± 0.1 mm tolerance)
  • Spacer thickness, diamond type: 44 mil / 1.1 mm
  • Membrane area: 6.0 m²
  • Outer wrap: FRP shell
  • All modules from GY-Series are delivered with attached ATDs.

Operating limits

Recommended operating conditions

  • Prefiltration: ≤ 75 µm
  • Cross flow (for water at 25 °C): 6 - 10 m³/h
  • Permeate pressure: 0 bar

Allowable operating conditions

  • Feed pressure, max.: 10 bar
  • Retentate pressure, min.: 0.7 bar
  • Transmembrane pressure, max.: 10 bar
  • Permeate pressure, max.: 0.35 bar
  • Pressure loss per module, max. (∆pmax):
    • 5 - 50 °C: 2 bar
    • 50 - 65 °C: 1.3 bar
    • 65 - 80 °C: 0.5 bar
  • Pressure loss per housing, max. at 80 °C: 2 bar
  • Processing temperature: 5 - 80 °C
  • pH range during filtration: 2 - 11
  • pH range during CIP: 1 - 12