Datasheet summary
WMC225 HYDRAcap40 UF module
PDF datasheet mirror for WMC225 HYDRAcap40 UF module (NX Filtration). Verify with OEM before design.
Summary
Product Identification
The WMC225 HYDRAcap series modules are hollow fiber ultrafiltration modules designed for water treatment, as well as industrial and municipal wastewater reuse. They are effective in removing turbidity, suspended solids, viruses, and bacteria, and offer outstanding pH and chlorine resistance. The series is available in different membrane surface areas.
Available Module Types:
- WMC225 HYDRAcap60+ (Product-Code: SETUF0033)
- WMC225 HYDRAcap60 (Product-Code: SETUF0032)
- WMC225 HYDRAcap40 (Product-Code: SETUF0030)
Membrane Characteristics
- Membrane material: Modified PES
- Membrane fiber inner diameter: 0.8 mm (0.031”)
- Pore size: 0.02 μm
- Molecular Weight Cut Off (MWCO): 150 kDa
- Note: MWCO is an estimation as it depends on size, shape, charge, and polarity of the compound being tested, as well as test conditions. Measured with dextran.
- Filtration mode: Inside-Out; Vertical
- Operation mode: Dead-end or cross-flow
- Typical flux: 50 – 100 l/m²/h (30 – 60 gfd)
- Backwash flux: 100 – 250 l/m²/h (60 - 150 gfd)
Operating Limits
- Max. system pressure: 3 bar (44 psi)
- Max. filtration transmembrane pressure: 1.5 bar (22 psi)
- Max. backwash pressure: 3 bar (44 psi)
- Max. active chlorine concentration: 500 ppm @ pH>10
- Max. cumulative active chlorine exposure: 250,000 ppm-hours @ pH>10
- Max. Temperature during operation & cleaning: 40°C (104°F)
- pH range during operation: 2-12
- pH range during cleaning: 1-13
Feed Water Parameters
- Max. particle size: 200 μm
- Max. TSS: 200 ppm
- Max. turbidity: 100 NTU
Materials of Construction
| Component | WMC225 HYDRAcap60+ | WMC225 HYDRAcap60 | WMC225 HYDRAcap40 |
|---|---|---|---|
| Housing | PVC-U | PVC-U | PVC-U |
| Internals | MBS, PP, Noryl | MBS, PP, Noryl | ABS, PP, PVC-U |
| Potting | Epoxy resin | Epoxy resin | Epoxy resin |
Dimensions and Weights
| Parameter | WMC225 HYDRAcap60+ | WMC225 HYDRAcap60 | WMC225 HYDRAcap40 |
|---|---|---|---|
| Membrane Surface Area | 56 m² (605 ft²) | 46 m² (500 ft²) | 30 m² (320 ft²) |
| L2.0 | 1600 mm (63”) | 1600 mm (63”) | 1092 mm (43”) |
| L2.1 | 1680 mm (66.13”) | 1680 mm (66.13”) | 1172 mm (46.13”) |
| L2.2 | 1710 mm (67.32”) | 1710 mm (67.32”) | 1202 mm (47.32”) |
| D2.0 | 60.3 mm (2.37”) | 60.3 mm (2.37”) | 60.3 mm (2.37”) |
| D2.1 | 60.3 mm (2.37”) | 60.3 mm (2.37”) | 60.3 mm (2.37”) |
| Empty weight Module including assembly components | 36.5 kg (80 lbs) | 34 kg (75 lbs) | 25 kg (55 lbs) |
| Filled module with assembly components | 87 kg (191 lbs) | 84 kg (185 lbs) | 57 kg (126 lbs) |
| Shipping weight per module | 43.5 kg (96 lbs) | 41 kg (90 lbs) | 29 kg (64 lbs) |
| Shipping weight per crate (12 modules) | 505 kg (1113 lbs) | 475 kg (1047 lbs) | 360 kg (794 lbs) |
Assembly Components
- WMC225 HYDRAcap Module
- Product end adapter
- O-ring #2-221 E70-150
- Plug Dead End
- O-ring #2-228 E70-150
- End cap Molded Ported
- End Cap Molded Nonported
- Plastic Clamp 4 Molded Endcap
- Washer D125-1A-M10-GALV
- Spring Washer D127B-M10-GALV
- Hex Bolt D931-M10x65-8.8zp
- Hex Nut D934-M10-Gr.08 zp
- O-ring #2-373 E70-150
Storage Information
New modules in original packaging can be stored for a maximum of 1 year from the shipping date. Store in a dry place, protected from sunlight or any heat source, at temperatures between 1 and 40°C (33 and 104°F).
Ex-factory storage solution: 84wt% water, 15wt% glycerin, and 1wt% sodium metabisulfite.
Shipping Information
Each module is individually packed in a vacuum-sealed plastic bag. For small quantities, modules are shipped in separate cardboard boxes. For large shipments, modules are loaded in a wooden crate with a maximum of 12 modules per crate.
- Crate dimensions WMC225 HYDRAcap40: 100 x 125 x 173 cm; 40 x 50 x 68 in (L x W x H)
- Crate dimensions WMC225 HYDRAcap60/60+: 100 x 125 x 191 cm; 40 x 50 x 75 in (L x W x H)
Weight stated is shipping weight including preservative solution.
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data and complete product information, always refer to the specific OEM PDF revision used on your project.