Datasheet summary
AsHR-4040
Engineering summary from PDF text extraction for AsHR-4040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: AsHR-4040
- Configuration: Spiral Wound
- Type: High Arsenic Removal - Nanofiltration Element
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Specifications
- Nominal Membrane Area: 85 ft² (7.9 m²)
- Permeate Flow: 2200 gpd (8.3 m³/d)
- Stabilized Salt Rejection: >97%
- Arsenic Removal (minimum): 97%
Operating limits
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Operating Pressure:
- Fiberglassed: 600 psi (41.4 bar)
- Tape Wrapped: 300 psi (20.7 bar)
- Maximum Feed Flow: 16 gpm (3.6 m³/h)
- Maximum Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum Ratio of Concentrate to Permeate Flow: 5:1 for any element
Test Conditions (Permeate Flow and Rejection)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 ÷ 7.0
- Solution: MgSO₄ 2000 ppm
- Applied Pressure: 70 psi (4.8 bar)
Mechanical / hydraulic
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension: 1.05 inches (26.7 mm)
- Weight: 8 lbs (3.6 Kg)
Operational Guidelines and Notices
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- Permeate flow for individual elements may vary +35% or -20%.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.
Disclaimer: This summary is based on text extracted from a PDF datasheet. This extraction may miss figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.