AsHR-8040

Engineering summary from PDF text extraction for AsHR-8040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: AsHR - 8040
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene
  • Type: High Arsenic Removal - Nanofiltration Element (Arsenic Removal minimum: 97%)

Specifications

  • Nominal Membrane Area: 400 ft² (37,2 m²)
  • Permeate Flow: 9500 gpd (36,0 m³/d)
  • Stabilized Salt Rejection: >97% (for MgSO₄)

Test Conditions

(After 30 min of operation)

  • Solution: MgSO₄ 2000 ppm
  • Applied Pressure: 70 psi (4,8 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6,5 ÷ 7,0

Operating limits

  • Maximum Operating Pressure: 600 psi (41,4 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 15 psi (1,0 bar)
  • Maximum Feed Flow: 75 gpm (17,0 m³/h)
  • Chlorine Concentration: <0,1 ppm
  • Feedwater SDI (15min): 5,0
  • Feedwater Turbidity: 1,0 NTU
  • Feedwater pH: 3,0 ÷ 10,0
  • Minimum ratio of concentrate to permeate flow: 5:1

Mechanical / hydraulic

  • Total Length (A): 40.0 inches (1016 mm)
  • ATD Diameter (B): 7.89 inches (200 mm)
  • Connection Int. Diameter (C): 1.125 inches (28,6 mm)
  • Weight: 36 lbs (16,4 Kg)

Notices

  • Permeate flow for individual elements may vary +35 or -20 percent.
  • Element is vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Element is supplied with interconnector.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure; damage is not covered under warranty.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading, use only silicon or glycerine to lubricate o-rings and brine seal.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.