Summary
Product Identification
- Model: BR2-2521
- Type: High Rejection, High Productivity - Brackish Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Specifications (Nominal Performance)
- Nominal Membrane Area: 12 ft² (1.1 m²)
- Permeate Flow: 330 gpd (1.2 m³/d)
- Salt Rejection: 99.4% nominal (98.0% minimum)
Test Conditions (for Nominal Performance)
- Solution: 1500 ppm NaCl
- Applied Pressure: 225 psi (15.5 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- pH Range: 6.5 ÷ 7.0
Operating Limits
- Maximum Feed Flow: 6 gpm (23 lpm)
- Maximum Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Operating Pressure:
- Fiberglassed: 600 psi (41.4 bar)
- Tape Wrapped: 300 psi (20.7 bar)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Feedwater pH: 3.0 ÷ 10.0
- Minimum ratio of concentrate to permeate flow: 5:1
Mechanical
- Total Length: 21.0 inches (533.4 mm)
- ATD Diameter: 2.4 inches (61 mm)
- Connection Diameter: 0.75 inches (19.1 mm)
- Core Tube Extension: 1.2 inches (30.5 mm)
- Weight: 2 lbs (0.9 Kg)
Installation and Operation Guidelines
- Discard permeate obtained from the first hour of operation.
- Avoid static permeate-side backpressure at all times.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- Minimum permeate flow for individual elements is 15 percent below listed flow.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.
Disclaimer: This summary is generated from an extracted text segment and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. For contractual data and comprehensive information, the official PDF revision used on the project must be consulted.