Back to OLTREMARE
OLTREMARE logo

Datasheet summary

BR2-2540

Engineering summary from PDF text extraction for BR2-2540. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: BR2-2540
  • Description: High Rejection, High Productivity - Brackish Water Element
  • Configuration: Spiral Wound

Specifications

  • Nominal Membrane Area: 28 ft² (2.6 m²)
  • Permeate Flow: 650 gpd (2.46 m³/d)
  • Salt Rejection: 99.4% nominal (98.0% minimum)

Test Conditions

(After 30 min of operation)

  • Solution: NaCl 1500 ppm
  • Applied Pressure: 225 psi (15.5 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6.5 ÷ 7.0

Dimensions and Weight

  • Total Length (A): 40.0 inches (1016 mm)
  • ATD Diameter (B): 2.4 inches (61 mm)
  • Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension: 1.2 inches (30.5 mm)
  • Weight: 4 lbs (1.8 Kg)

Maximum Operating Limits

  • Feed Flow: 6 gpm (23 lpm)
  • Chlorine Concentration: <0.1 ppm
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)

Other Operating Limits

  • Pressure Drop: 10 psi (0.7 bar)
  • Temperature: 113 °F (45 °C)
  • Feedwater pH: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Materials of Construction

  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

General Guidelines

  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • Minimum permeate flow for individual elements is 15 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure; damage is not covered under warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.