Back to OLTREMARE
OLTREMARE logo

Datasheet summary

BR2-4040

Engineering summary from PDF text extraction for BR2-4040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: BR2-4040
  • Description: High Rejection, High Productivity - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene
  • Nominal Membrane Area: 85 ft² (7.9 m²)
  • Permeate Flow: 2300 gpd (8.7 m³/d)
  • Salt Rejection: 99.5% nominal (99.2% minimum)

Operating limits

  • Maximum Feed Flow: 16 gpm (3.6 m³/h)
  • Maximum Chlorine Concentration: <0.1 ppm
  • Maximum Feedwater SDI (15min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Feedwater pH: 3.0 ÷ 10.0
  • Minimum concentrate to permeate flow ratio: 5:1
  • Avoid static permeate-side backpressure at all times.

Feed water

  • pH Range: 3.0 ÷ 10.0
  • Maximum Chlorine Concentration: <0.1 ppm
  • Maximum SDI (15min): 5.0
  • Maximum Turbidity: 1.0 NTU

Test Conditions (for stated performance)

  • Solution: 1500 ppm NaCl
  • Applied Pressure: 225 psi (15.5 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 ÷ 7.0

Mechanical / hydraulic

  • Dimensions:
    • Total Length: 40.0 inches (1016 mm)
    • ATD Diameter: 3.95 inches (100.3 mm)
    • Connection Diameter: 0.75 inches (19.1 mm)
    • Core Tube Extension: 1.05 inches (26.7 mm)
  • Weight: 8 lbs (3.6 Kg)

Important Notes

  • Permeate flow for individual elements may vary ±15 percent.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure; damage is not covered under warranty.
  • Permeate obtained from the first hour of operation should be discarded.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.

Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions from the complete OEM PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.