Datasheet summary
BR3-8040
Engineering summary from PDF text extraction for BR3-8040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: BR3-8040
- Description: High Rejection, Excellent Productivity - Brackish Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Operating limits
- Maximum Feed Flow: 75 gpm (17.0 m³/h)
- Maximum Chlorine Concentration: < 0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Operating Pressure: 600 psi (41.4 bar)
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum Ratio of Concentrate to Permeate Flow: 5:1
Performance specifications
(Performance data based on test conditions)
- Nominal Membrane Area: 400 ft² (37.2 m²)
- Permeate Flow: 11000 gpd (41.6 m³/d)
- Salt Rejection: 99.5% nominal (99.2% minimum)
Test conditions
(After 30 min of operation)
- Solution: 1500 ppm NaCl
- Applied Pressure: 225 psi (15.5 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 ÷ 7.0
Mechanical / hydraulic
- Dimensions:
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 7.89 inches (200 mm)
- Connection Int. Diameter (C): 1.125 inches (28.6 mm)
- Weight: 36 lbs (16.4 Kg)
Notices and guidelines
- Permeate flow for individual elements may vary +25% or -15%.
- The element is vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- The element is supplied with an interconnector.
- The customer is fully responsible for the effects of incompatible chemicals on elements.
- The presence of free chlorine and other oxidizing agents will cause membrane failure; damage is not covered under warranty.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.