Datasheet summary
FOUL1-2540
Engineering summary from PDF text extraction for FOUL1-2540. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: FOUL1-2540
- Type: Low Fouling, Neutral Charged - Brackish Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Nominal Performance
Based on the following test conditions:
- Solution: 1500 ppm NaCl
- Applied Pressure: 225 psi (15.5 bar)
- Operating Temperature: 77 °F (25 °C)
- Recovery: 10%
- Permeate pH (After 30 min of operation): 6.5 ÷ 7.0
Performance specifications:
- Nominal Permeate Flow: 650 gpd (2.5 m³/d)
- Salt Rejection: 98.0% minimum
- Nominal Membrane Area: 28 ft² (2.6 m²)
Mechanical / hydraulic
Dimensions:
- Total Length (A): 40.0 inches (1016 mm)
- Diameter (B): 2.4 inches (61 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
- Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
- Weight: 4 lbs (1.8 Kg)
Operating limits
- Operating Pressure:
- Fiberglassed: 600 psi (41.4 bar)
- Tape Wrapped: 300 psi (20.7 bar)
- Temperature: 113 °F (45 °C)
- Pressure Drop: 10 psi (0.7 bar)
- Maximum Flow: 6 gpm (23 lpm)
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Feed water
- Chlorine Concentration: <0.1 ppm
- SDI (15min): 5.0
- Turbidity: 1.0 NTU
Product water
- Minimum permeate flow for individual elements 15 percent below listed flow.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
Handling and Storage Notes
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.
Disclaimer