FOUL1-4040

Engineering summary from PDF text extraction for FOUL1-4040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: FOUL1-4040
  • Type: Low Fouling, Neutral Charged - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide, Neutrally charged
  • Brine Spacer Material: Polypropylene
  • Nominal Membrane Flow: 2000 gpd (7,6 m³/d)
  • Salt Rejection: 99,4% nominal (99,0% minimum)
  • Nominal Membrane Area: 75 ft² (7,0 m²)

Test Conditions

(After 30 min of operation)

  • Solution: 1500 ppm NaCl
  • Applied Pressure: 225 psi (15,5 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 – 7.0

Dimensions

  • A Total Length: 40.0 inches (1016 mm)
  • B ATD Diameter: 3.95 inches (100,3 mm)
  • C Connection Diameter: 0.75 inches (19,1 mm)
  • DF Core Tube Extension Feed Side: 1.05 inches (26,7 mm)
  • DC Core Tube Extension Conc. Side: 1.05 inches (26,7 mm)
  • Weight: 8 lbs (3,6 Kg)

Operating limits

  • Maximum Operating Pressure:
    • Fiberglassed: 600 psi (41,4 bar)
    • Tape Wrapped: 300 psi (20,7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0,7 bar)
  • Maximum Feed Flow: 16 gpm (3,6 m³/h)
  • Maximum Feed Chlorine Concentration: <0,1 ppm
  • Maximum Feedwater SDI (15min): 5,0
  • Maximum Feedwater Turbidity: 1,0 NTU
  • Feedwater pH Range: 3.0 – 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Notices and Guidelines

  • Permeate flow for individual elements may vary ±15 percent.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and damage is not covered under warranty.

Disclaimer

This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. The customer is responsible for verifying the appropriateness of the product for specific uses. No performance warranties are given; all implied warranties of merchantability or fitness for a particular purpose are expressly excluded. Contractual data must match the OEM PDF revision used on the project.