FOUL1-8040

Engineering summary from PDF text extraction for FOUL1-8040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: FOUL1-8040
  • Type: Low Fouling - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Specifications

  • Nominal Membrane Area: 365 ft² (34.0 m²)
  • Permeate Flow: 9800 gpd (37.1 m³/d)
  • Salt Rejection: 99.5% nominal (99.0% minimum)

Test Conditions

(After 30 min of operation)

  • Solution: NaCl 1500 ppm
  • Applied Pressure: 225 psi (15.5 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 ÷ 7.0

Operating limits

  • Maximum Operating Pressure: 600 psi (41.4 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Feed Flow: 75 gpm (17.0 m³/h)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Chlorine Concentration: <0.1 ppm
  • Feedwater pH: 2.0 ÷ 11.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow: 5:1 for any element

Mechanical / hydraulic

  • Total Length (A): 40.0 inches (1016 mm)
  • ATD Diameter (B): 7.89 inches (200 mm)
  • Connection Int. Diameter (C): 1.125 inches (28.6 mm)
  • Weight: 36 lbs (16.4 Kg)

General Notes

  • Permeate flow for individual element may vary +25 or -15 percent.
  • Element is vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Element is supplied with interconnector.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, which is not covered under warranty.