Back to OLTREMARE
OLTREMARE logo

Datasheet summary

LOW1-4014

Engineering summary from PDF text extraction for LOW1-4014. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW1-4014
  • Type: Low Energy, Very High Rejection - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance specifications

(Based on standard test conditions)

  • Permeate Flow: 600 gpd (2.3 m³/d)
  • Salt Rejection: 99.0% nominal (98.0% minimum)
  • Nominal Membrane Area: 19 ft² (1.8 m²)

Test Conditions:

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6.5 ÷ 7.0 (After 30 min of operation)

Operating limits

  • Maximum Operating Pressure (Fiberglassed): 600 psi (41.4 bar)
  • Maximum Operating Pressure (Tape Wrapped): 300 psi (20.7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 12 gpm (45.4 lpm)
  • Maximum Feed Chlorine Concentration: <0.1 ppm
  • Maximum Feedwater SDI (15min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Mechanical / hydraulic

  • Length (A): 14.0 inches (355.6 mm)
  • Diameter (B): 3.95 inches (100.3 mm)
  • Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
  • Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
  • Weight: 3 lbs (1.4 Kg)

General guidelines and notices

  • Minimum permeate flow for individual elements is 15 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; users should check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.

Disclaimer: This summary is based solely on the extracted text provided. The original PDF may contain additional figures, footnotes, or more recent revisions. For contractual data, please refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.