Datasheet summary
LOW1-4014-XL
Engineering summary from PDF text extraction for LOW1-4014-XL. Verify every value with the OEM datasheet.
Summary
Product identification
The LOW1-4014-XL is an Extra Area, Low Energy, Very High Rejection, Brackish Water reverse osmosis element.
Specifications
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
- Nominal Membrane Area: 25 ft² (2.3 m²)
Performance
- Permeate Flow: 800 gpd (3.03 m³/d)
- Salt Rejection: 99.0% nominal (98.0% minimum)
Test Conditions
- NaCl Solution: 1500 ppm
- Applied Pressure: 150 psi (10.3 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- pH Range: 6.5 ÷ 7.0 (After 30 min of operation)
Mechanical / Hydraulic
Dimensions
- Total Length (A): 14.0 inches (355.6 mm)
- Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
- Core Tube Extension Concentrate Side (DC): 1.2 inches (30.5 mm)
- Weight: 3 lbs (1.4 Kg)
Operating limits
- Maximum Operating Pressure: 300 psi (20.7 bar)
- Maximum Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Feed Flow: 12 gpm (45.4 lpm)
- Maximum Feed Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Notices & Guidelines
- The limitations shown are for general use. Project-specific values may be more conservative.
- Minimum permeate flow for individual elements may be 20 percent below the listed flow.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The presence of free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.