Datasheet summary
LOW1-4040
Engineering summary from PDF text extraction for LOW1-4040. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: LOW1-4040
- Type: Low Energy, Very High Rejection - Brackish Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Performance Specifications
- Nominal Permeate Flow: 2600 gpd (9.8 m³/d)
- Nominal Salt Rejection: 99.3% (99.0% minimum)
- Nominal Membrane Area: 85 ft² (7.9 m²)
Performance Test Conditions
(After 30 min of operation)
- Solution: 1500 ppm NaCl
- Applied Pressure: 150 psi (10.3 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 ÷ 7.0
Operating Limits
- Maximum Operating Pressure (Fiberglassed): 600 psi (41.4 bar)
- Maximum Operating Pressure (Tape Wrapped): 300 psi (20.7 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Feed Flow: 16 gpm (3.6 m³/h)
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Feed Water Specifications
- Feedwater pH Range: 3.0 ÷ 10.0
- Maximum Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
Mechanical / Hydraulic
- Dimensions:
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.05 inches (26.7 mm)
- Core Tube Extension Conc. Side (DC): 1.05 inches (26.7 mm)
- Weight: 8 lbs (3.6 Kg)
General Information & Guidelines
- Permeate flow for individual elements may vary ±15 percent.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
- For element loading, use only glycerine to lubricate O-rings and brine seal.
- The customer is fully responsible for the effects of incompatible chemicals on elements.
- The presence of free chlorine and other oxidizing agents will cause membrane failure; this damage is not covered under warranty.
Disclaimer