Datasheet summary
LOW1-8040
Engineering summary from PDF text extraction for LOW1-8040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: LOW1-8040
- Type: Low Energy, Very High Rejection - Brackish Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Specifications
- Nominal Membrane Area: 400 ft² (37.2 m²)
- Permeate Flow: 12000 gpd (45.4 m³/d)
- Salt Rejection: 99.3% nominal (99.0% minimum)
Test Conditions
(After 30 min of operation)
- Solution: NaCl 1500 ppm
- Applied Pressure: 150 psi (10.3 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 ÷ 7.0
Operating limits
- Maximum Operating Pressure: 600 psi (41.4 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Feed Flow: 75 gpm (17.0 m³/h)
- Chlorine Concentration: <0.1 ppm
- Feedwater SDI (15min): 5.0
- Feedwater Turbidity: 1.0 NTU
- Feedwater pH: 3.0 ÷ 10.0
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Minimum ratio of concentrate to permeate flow: 5:1 for any element
Mechanical / hydraulic
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 7.89 inches (200 mm)
- Connection Internal Diameter (C): 1.125 inches (28.6 mm)
- Weight: 36 lbs (16.4 Kg)
Product handling and storage
- Permeate flow for individual element may vary +25% or -15%.
- Element is vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- Element is supplied with interconnector.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- For element loading, use only glycerine to lubricate o-rings and brine seal.