Summary

Product identification

The product is a LOW2-2521 Low Energy, Excellent Rejection Brackish Water Element.

  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance specifications

The element offers low energy operation and excellent rejection for brackish water applications.

  • Nominal Permeate Flow: 280 gpd (1.1 m³/d)
  • Nominal Salt Rejection: 99.4% (99.0% minimum)
  • Nominal Membrane Area: 12 ft² (1.1 m²)

Test Conditions:

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range (after 30 min operation): 6.5 ÷ 7.0

Operating limits

These are general limits; specific projects may require more conservative values for optimal performance and membrane lifespan.

  • Maximum Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 6 gpm (23 lpm)
  • Maximum Chlorine Concentration: <0.1 ppm
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow: 5:1

Mechanical / hydraulic

  • Dimensions:
    • Total Length (A): 21.0 inches (533.4 mm)
    • Diameter (B): 2.4 inches (61 mm)
    • Connection Diameter (C): 0.75 inches (19.1 mm)
    • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
    • Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
  • Weight: 2 lbs (0.9 Kg)

Guidelines and Notices

  • Minimum permeate flow for individual elements can be 15 percent below the listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • The permeate obtained during the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; users should check the application status before use and sale.
  • For element loading, use only glycerine to lubricate O-rings and the brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.