Datasheet summary
LOW2-2540
Engineering summary from PDF text extraction for LOW2-2540. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: LOW2-2540
- Type: Low Energy, Excellent Rejection - Brackish Water Element
Specifications
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Performance
- Nominal Permeate Flow: 550 gpd (2.1 m³/d)
- Salt Rejection: 99.4% nominal (99.0% minimum)
- Nominal Membrane Area: 28 ft² (2.6 m²)
Test Conditions
(After 30 min of operation)
- Solution: 1500 ppm NaCl
- Applied Pressure: 150 psi (10.3 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- pH Range: 6.5 ÷ 7.0
Dimensions and Weight
- Total Length (A): 40.0 inches (1016 mm)
- Total Diameter (B): 2.4 inches (61 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
- Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
- Weight: 4 lbs (1.8 Kg)
Maximum Operating Limits
- Operating Pressure:
- Fiberglassed: 600 psi (41.4 bar)
- Tape Wrapped: 300 psi (20.7 bar)
- Temperature: 113 °F (45 °C)
- Pressure Drop: 10 psi (0.7 bar)
- Feed Flow: 6 gpm (23 lpm)
- Feedwater Chlorine Concentration: <0.1 ppm
- Feedwater pH Range: 3.0 ÷ 10.0
- Feedwater SDI (15min): 5.0
- Feedwater Turbidity: 1.0 NTU
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Notices and Guidelines
- Minimum permeate flow for individual elements is 15 percent below listed flow.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all time.
- These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.
Disclaimer: This summary is based on the extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.