Back to OLTREMARE
OLTREMARE logo

Datasheet summary

LOW2-4014

Engineering summary from PDF text extraction for LOW2-4014. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW2-4014
  • Type: Low Energy, Excellent Rejection - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance

  • Nominal Permeate Flow: 370 gpd (1,4 m³/d)
  • Nominal Salt Rejection: 99,4% (99,0% minimum)
  • Nominal Membrane Area: 19 ft² (1,8 m²)

Test Conditions

(After 30 min of operation)

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psi (10,3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6,5 ÷ 7,0

Mechanical / Hydraulic

  • Total Length (A): 14.0 inches (355,6 mm)
  • Diameter (B): 3.95 inches (100,3 mm)
  • Connection Diameter (C): 0.75 inches (19,1 mm)
  • Core Tube Extension Feed Side (DF): 1.2 inches (30,5 mm)
  • Core Tube Extension Conc. Side (DC): 1.2 inches (30,5 mm)
  • Weight: 3 lbs (1,4 Kg)

Operating limits

  • Maximum Operating Pressure:
    • Fiberglassed: 600 psi (41,4 bar)
    • Tape Wrapped: 300 psi (20,7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0,7 bar)
  • Maximum Feed Flow: 12 gpm (45,4 lpm)
  • Maximum Feed Chlorine Concentration: <0,1 ppm
  • Maximum Feedwater SDI (15min): 5,0
  • Maximum Feedwater Turbidity: 1,0 NTU
  • Feedwater pH: 3,0 ÷ 10,0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Other Operating Information

  • Minimum permeate flow for individual elements is 15 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading, use only glycerine to lubricate O-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure; this damage is not covered under warranty.

Disclaimer

This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.