Back to OLTREMARE
OLTREMARE logo

Datasheet summary

LOW2-4014-XL

Engineering summary from PDF text extraction for LOW2-4014-XL. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: LOW2-4014-XL
  • Description: Extra Area - Low Energy, Excellent Rejection - Brackish Water Element
  • Type:
    • Configuration: Spiral Wound
    • Membrane Polymer: Composite Polyamide
    • Brine Spacer Material: Polypropylene

Performance Specifications

  • Permeate Flow: 500 gpd (1.89 m³/d)
  • Nominal Salt Rejection: 99.4%
  • Minimum Salt Rejection: 99.0%
  • Nominal Membrane Area: 25 ft² (2.3 m²)
  • Test Conditions:
    • NaCl Solution: 1500 ppm
    • Applied Pressure: 150 psi (10.3 bar)
    • Operating Temperature: 77 °F (25 °C)
    • Permeate Recovery: 10%
    • pH Range (After 30 min of operation): 6.5 ÷ 7.0

Mechanical / Hydraulic

  • Dimensions:
    • A (Total Length): 14.0 inches (355.6 mm)
    • B (Diameter): 3.95 inches (100.3 mm)
    • C (Connection Diameter): 0.75 inches (19.1 mm)
    • DF (Core Tube Extension - Feed Side): 1.2 inches (30.5 mm)
    • DC (Core Tube Extension - Concentrate Side): 1.2 inches (30.5 mm)
  • Weight: 3 lbs (1.4 Kg)

Operating Limits

  • Maximum Operating Pressure: 300 psi (20.7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 12 gpm (45.4 lpm)
  • Maximum Chlorine Concentration: <0.1 ppm
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Notices & Guidelines

  • Minimum permeate flow for individual elements is 20 percent below the listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.

Disclaimer: This summary is based on the provided text extraction and may not include all figures, footnotes, or the latest revisions from the official OEM PDF datasheet. Contractual data must always match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.