Back to OLTREMARE
OLTREMARE logo

Datasheet summary

LOW2-4040

Engineering summary from PDF text extraction for LOW2-4040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW2-4040
  • Type: Low Energy, Excellent Rejection - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Specifications

  • Permeate Flow: 1900 gpd (7.2 m³/d)
  • Salt Rejection: 99.6% nominal (99.4% minimum)
  • Nominal Membrane Area: 85 ft² (7.9 m²)

Test Conditions

(After 30 min of operation)

  • Solution: 1500 ppm NaCl
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 ÷ 7.0

Dimensions

  • A Total Length: 40.0 inches (1016 mm)
  • B ATD Diameter: 3.95 inches (100.3 mm)
  • C Connection Diameter: 0.75 inches (19.1 mm)
  • DF Core Tube Extension Feed Side: 1.05 inches (26.7 mm)
  • DC Core Tube Extension Concentrate Side: 1.05 inches (26.7 mm)
  • Weight: 8 lbs (3.6 Kg)

Operating limits

  • Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)
  • Temperature: 113 °F (45 °C)
  • Pressure Drop: 10 psi (0.7 bar)
  • Feed Flow: 16 gpm (3.6 m³/h)
  • Chlorine Concentration: < 0.1 ppm
  • Feedwater SDI (15 min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

General Guidelines

  • Permeate flow for individual elements may vary + or -15 percent.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure; damage is not covered under warranty.

Disclaimer

This summary is based on extracted text and may miss figures, footnotes, or the latest revisions. The customer is fully responsible for the effects of incompatible chemicals on elements. Contractual data must match the OEM PDF revision used on the project.