Back to OLTREMARE
OLTREMARE logo

Datasheet summary

LOW2-8040

Engineering summary from PDF text extraction for LOW2-8040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW2-8040
  • Description: Low Energy, Excellent Rejection - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Product water

  • Nominal Membrane Area: 400ft² (37.2m²)
  • Permeate Flow: 9000 gpd (34.1 m³/d)
  • Salt Rejection: 99.6% nominal (99.5% minimum)

Test Conditions (After 30 min of operation):

  • Solution: NaCl 1500 ppm
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 ÷ 7.0

Mechanical / hydraulic

  • Total Length (A): 40.0 inches (1016 mm)
  • ATD Diameter (B): 7.89 inches (200 mm)
  • Connection Int. Diameter (C): 1.125 inches (28.6 mm)
  • Weight: 36 lbs (16.4 Kg)

Operating limits

  • Maximum Operating Pressure: 600 psi (41.4 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 75 gpm (17.0 m³/h)
  • Chlorine Concentration: <0.1 ppm
  • Feedwater pH: 3.0 ÷ 10.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

General information

  • Permeate flow for individual element may vary +25 or -15 percent.
  • Element is vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Element is supplied with interconnector.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, which is not covered under warranty.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading use only glycerine to lubricate o-rings and brine seal.

Disclaimer: This summary is based solely on the extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF. Contractual data must match the specific OEM PDF revision used on the project.