Product identification

  • Model: LOW3-2521
  • Description: Low Energy, Excellent Productivity - Brackish Water Element

Specifications

  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance Data

  • Permeate Flow: 420 gpd (1.6 m³/d)
  • Salt Rejection: 98.5% nominal (97.0% minimum)
  • Nominal Membrane Area: 12 ft² (1.1 m²)

Test Conditions

Performance data is measured under the following conditions (after 30 min of operation):

  • NaCl Solution: 1500 ppm
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6.5 ÷ 7.0

Operating limits

  • Maximum Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 6 gpm (23 lpm)
  • Maximum Chlorine Concentration: <0.1 ppm
  • Maximum Feedwater SDI (15min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Mechanical / hydraulic

  • Dimensions:
    • Total Length (A): 21.0 inches (533.4 mm)
    • Total Diameter (B): 2.4 inches (61 mm)
    • Connection Diameter (C): 0.75 inches (19.1 mm)
    • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
    • Core Tube Extension Concentrate Side (DC): 1.2 inches (30.5 mm)
  • Weight: 2 lbs (0.9 Kg)

General Notes and Warnings

  • Minimum permeate flow for individual elements is 15 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; users should check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The customer is fully responsible for the effects of incompatible chemicals on elements.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.