Datasheet summary

LOW3-2540

Engineering summary from PDF text extraction for LOW3-2540. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW3-2540
  • Type: Low Energy, Excellent Productivity - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance specifications

  • Permeate Flow: 900 gpd (3.4 m³/d)
  • Salt Rejection: 98.5% nominal (97.0% minimum)
  • Nominal Membrane Area: 28 ft² (2.6 m²)

Test Conditions

  • Solution: 1500 ppm NaCl
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range (After 30 min of operation): 6.5 ÷ 7.0

Mechanical / hydraulic

  • Weight: 4 lbs (1.8 Kg)
  • Dimensions:
    • Length (A): 40.0 inches (1016 mm)
    • Total Diameter (B): 2.4 inches (61 mm)
    • Connection Diameter (C): 0.75 inches (19.1 mm)
    • Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
    • Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)

Operating limits

  • Maximum Operating Pressure:
    • Fiberglassed: 600 psi (41.4 bar)
    • Tape Wrapped: 300 psi (20.7 bar)
  • Maximum Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 6 gpm (23 lpm)
  • Maximum Chlorine Concentration: <0.1 ppm
  • Feedwater pH Range: 3.0 ÷ 10.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

Notices and Guidelines

  • Minimum permeate flow for individual elements is 15 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure, the damage is not covered under warranty.