Datasheet summary
LOW3-4014-XL
Engineering summary from PDF text extraction for LOW3-4014-XL. Verify every value with the OEM datasheet.
Summary
Product identification
The AquaChain OLTREMARE LOW3-4014-XL is an Extra Area - Low Energy, Excellent Productivity - Brackish Water Element.
- Type: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Performance Specifications
- Nominal Permeate Flow: 850 gpd (3.22 m³/d)
- Nominal Salt Rejection: 98.5% (97.5% minimum)
- Nominal Membrane Area: 25 ft² (2.3 m²)
Test Conditions
Performance specifications are based on the following test conditions:
- Solution: 1500 ppm NaCl
- Applied Pressure: 150 psi (10.3 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- pH Range (Permeate): 6.5 ÷ 7.0 (after 30 min of operation)
Mechanical / hydraulic
- Length: 14.0 inches (355.6 mm)
- Diameter: 3.95 inches (100.3 mm)
- Connection Diameter: 0.75 inches (19.1 mm)
- Core Tube Extension (Feed Side): 1.2 inches (30.5 mm)
- Core Tube Extension (Concentrate Side): 1.2 inches (30.5 mm)
- Weight: 3 lbs (1.4 Kg)
Operating limits
- Maximum Operating Pressure: 300 psi (20.7 bar)
- Maximum Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Feed Flow: 12 gpm (45.4 lpm)
- Feedwater Chlorine Concentration: <0.1 ppm
- Feedwater SDI (15min): 5.0
- Feedwater Turbidity: 1.0 NTU
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum ratio of concentrate to permeate flow for any element: 5:1
The limitations shown in Operating Limits are for general use. The values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.
Notices and Guidelines
- Minimum permeate flow for individual elements is 20 percent below listed flow.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries: please check the application status before use and sale.
- For element loading use only glycerine to lubricate o-rings and brine seal.
- The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure; the damage is not covered under warranty.
Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions present in the official OEM PDF. Contractual data must always match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.