LOW3-4040

Engineering summary from PDF text extraction for LOW3-4040. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW3-4040
  • Description: Low Energy, Excellent Productivity - Brackish Water Element
  • Type: Spiral Wound

Specifications

  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Performance

  • Permeate Flow: 3000 gpd (11.4 m³/d)
  • Salt Rejection: 98.8% nominal (98.0% minimum)
  • Nominal Membrane Area: 85 ft² (7.9 m²)
  • Note: Permeate flow for individual elements may vary + or -15 percent.

Test Conditions

(After 30 min of operation)

  • Solution: 1500 ppm NaCl
  • Applied Pressure: 150 psi (10.3 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 15%
  • pH Range: 6.5 ÷ 7.0

Operating limits

  • Maximum Operating Pressure: 600 psi (41.4 bar)
  • Maximum Operating Temperature: 113 °F (45 °C)
  • Maximum Pressure Drop: 10 psi (0.7 bar)
  • Maximum Feed Flow: 16 gpm (3.6 m³/h)
  • Maximum Feedwater Chlorine Concentration: < 0.1 ppm
  • Maximum Feedwater SDI (15min): 5.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Feedwater pH: 3.0 ÷ 10.0
  • Minimum ratio of concentrate to permeate flow (for any element): 5:1

Mechanical / hydraulic

  • Total Length: 40.0 inches (1016 mm)
  • ATD Diameter: 3.95 inches (100.3 mm)
  • Connection Diameter: 0.75 inches (19.1 mm)
  • Core Tube Extension (Feed Side): 1.05 inches (26.7 mm)
  • Core Tube Extension (Conc. Side): 1.05 inches (26.7 mm)
  • Weight: 8 lbs (3.6 Kg)

General Guidelines

  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; check application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.

Disclaimer: This summary is based solely on the provided text extract. The original OEM PDF may contain additional figures, footnotes, or more recent revisions. For contractual data, always refer to the specific OEM PDF revision used on your project.