Back to OLTREMARE
OLTREMARE logo

Datasheet summary

LOW4-2514

Engineering summary from PDF text extraction for LOW4-2514. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: LOW4-2514
  • Type: Extra Low Energy, Excellent Productivity - Brackish Water Element
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Brine Spacer Material: Polypropylene

Specifications

  • Permeate Flow: 150 gpd (0.57 m³/d)
  • Salt Rejection: 99.0% nominal (98.0% minimum)
  • Nominal Membrane Area: 6 ft² (0.6 m²)

Test Conditions

(After 30 min of operation)

  • NaCl Solution: 500 ppm
  • Applied Pressure: 100 psi (6.9 bar)
  • Operating Temperature: 77 °F (25 °C)
  • Permeate Recovery: 10%
  • pH Range: 6.5 ÷ 7.0

Mechanical / hydraulic

  • Total Length (A): 14.0 inches (355.6 mm)
  • Total Diameter (B): 2.4 inches (61 mm)
  • Connection Diameter (C): 0.75 inches (19.1 mm)
  • Core Tube Extension (Feed Side DF): 1.2 inches (30.5 mm)
  • Core Tube Extension (Conc. Side DC): 1.2 inches (30.5 mm)
  • Weight: 1 lbs (0.45 Kg)

Operating limits

  • Operating Pressure (Fiberglassed): 600 psi (41.4 bar)
  • Operating Pressure (Tape Wrapped): 300 psi (20.7 bar)
  • Temperature: 113 °F (45 °C)
  • Pressure Drop: 10 psi (0.7 bar)
  • Feed Flow: 6 gpm (23 lpm)
  • Chlorine Concentration: <0.1 ppm
  • Feedwater pH: 3.0 ÷ 10.0
  • Feedwater SDI (15min): 5.0
  • Feedwater Turbidity: 1.0 NTU
  • Minimum ratio of concentrate to permeate flow for any element: 5:1

General Guidelines

  • Minimum permeate flow for individual elements is 20 percent below listed flow.
  • Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite and 10% propylene glycol solution.
  • Permeate obtained from the first hour of operation should be discarded.
  • Avoid static permeate-side backpressure at all times.
  • These membranes may be subject to drinking water application restrictions in some countries; users should check the application status before use and sale.
  • For element loading, use only glycerine to lubricate o-rings and brine seal.
  • The presence of free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.

Disclaimer: This summary is based on the provided text extraction and may miss figures, footnotes, or revisions present in the full OEM PDF. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.