Datasheet summary
NANO7-4040
Engineering summary from PDF text extraction for NANO7-4040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: NANO7-4040
- Type: Ultra Low Energy, Excellent Ion Selective - Nanofiltration Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Performance Specifications
(Tested with 2000 ppm MgSO₄ solution at 70 psi (4.8 bar) applied pressure, 77 °F (25 °C) operating temperature, 15% permeate recovery, and pH 6.5 – 7.0 after 30 minutes of operation.)
- Permeate Flow: 2500 gpd (9.5 m³/d)
- Stabilized Salt Rejection: >97%
- Nominal Membrane Area: 85 ft² (7.9 m²)
Operating limits
- Maximum Operating Pressure: 600 psi (41.4 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Feed Flow: 16 gpm (3.6 m³/h)
- Maximum Chlorine Concentration: <0.1 ppm
- Feedwater pH Range: 3.0 – 10.0
- Maximum SDI (15min): 5.0
- Maximum Turbidity: 1.0 NTU
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Mechanical / hydraulic
- Total Length (A): 40.0 inches (1016 mm)
- ATD Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.05 inches (26.7 mm)
- Core Tube Extension Conc. Side (DC): 1.05 inches (26.7 mm)
- Weight: 8 lbs (3.6 Kg)
Guidelines
- Permeate flow for individual elements may vary +35% or -20%.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- For element loading, use only silicon or glycerine to lubricate o-rings and brine seal.
- The presence of free chlorine and other oxidizing agents will cause membrane failure; damage is not covered under warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual purposes, data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.