Datasheet summary
NANO9-4021
Engineering summary from PDF text extraction for NANO9-4021. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: NANO9-4021
- Type: Ultra Low Energy, Excellent Ion Selective - Nanofiltration Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Product water
The element performance is tested under specific conditions:
- Permeate Flow: 840 gpd (3.2 m³/d)
- Stabilized Salt Rejection: >97%
- Nominal Membrane Area: 35 ft² (3.2 m²)
Test Conditions (after 30 min of operation)
- Test Solution: 2000 ppm MgSO₄
- Applied Pressure: 70 psi (4.8 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- pH Range: 6.5 ÷ 7.0
Mechanical / hydraulic
Dimensions
- Total Length: 21.0 inches (533.4 mm)
- Diameter: 3.95 inches (100.3 mm)
- Connection Diameter: 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side: 1.2 inches (30.5 mm)
- Core Tube Extension Concentrate Side: 1.2 inches (30.5 mm)
- Weight: 4 lbs (1.8 Kg)
Operating limits
- Maximum Operating Pressure (Fiberglassed): 600 psi (41.4 bar)
- Maximum Operating Pressure (Tape Wrapped): 300 psi (20.7 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Feed Flow: 12 gpm (45.4 lpm)
- Maximum Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15 min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Feedwater pH Range: 3.0 ÷ 10.0
- Minimum Ratio of Concentrate to Permeate Flow for any element: 5:1
General Guidelines
- Minimum permeate flow for individual elements is 20 percent below listed flow.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The presence of free chlorine and other oxidizing agents will cause membrane failure; the damage is not covered under warranty.