Datasheet summary
NANO9-4040
Engineering summary from PDF text extraction for NANO9-4040. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: NANO9-4040
- Description: Ultra Low Energy, Excellent Ion Selective - Nanofiltration Element
- Configuration: Spiral Wound
- Nominal Membrane Area: 85 ft² (7.9 m²)
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Test Conditions
(After 30 minutes of operation)
- Permeate Flow: 2000 gpd (8.3 m³/d)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 15%
- pH Range: 6.5 ÷ 7.0
- Solution: MgSO₄ 2000 ppm
- Applied Pressure: 70 psi (4.8 bar)
- Stabilized Salt Rejection: >97%
Operating limits
- Maximum Feed Flow: 16 gpm (3.6 m³/h)
- Chlorine Concentration: <0.1 ppm
- Feedwater SDI (15min): 5.0
- Feedwater Turbidity: 1.0 NTU
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Temperature: 113 °F (45 °C)
- Maximum Operating Pressure:
- Fiberglassed: 600 psi (41.4 bar)
- Tape Wrapped: 300 psi (20.7 bar)
- Feedwater pH: 3.0 ÷ 10.0
- Minimum ratio of concentrate to permeate flow: 5:1 for any element
Mechanical / hydraulic
- Total Length (A): 40.0 inches (1016 mm)
- Diameter (B): 3.95 inches (100.3 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension: 1.05 inches (26.7 mm)
- Weight: 8 lbs (3.6 Kg)
General Guidelines and Notices
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; check application status before use and sale.
- For element loading, use only glycerine to lubricate O-rings and brine seal.
- Permeate flow for individual elements may vary +35% or -20%.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- The customer is responsible for the effects of incompatible chemicals. Free chlorine and other oxidizing agents will cause membrane failure, and such damage is not covered under warranty.
Disclaimer: This summary is generated from extracted text and may not include all figures, footnotes, or the latest revisions found in the official PDF datasheet. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.