Datasheet summary
OLTREcap-0640-M
Engineering summary from PDF text extraction for OLTREcap-0640-M. Verify every value with the OEM datasheet.
Summary
Product Identification
These are OLTRESUB-M Submerged MBR Membrane Modules.
- Membrane Material: PVDF
- Membrane Configuration: Capillary
- Normalized Filtration Pore Size: 0.075µm
- Potting Material: Epoxy
- Housing Material: PVC/ABS
- Membrane ID/OD: 0.9/1.5 mm (0.035/0.059”)
- Preservative: Glycerin (35%)
Module Specifications:
- OLTRESUB-0640-M: 14m² (150.7 ft²) membrane area
- OLTRESUB-0660-M: 22m² (236.8 ft²) membrane area
- OLTRESUB-0680-M: 30m² (322.9 ft²) membrane area
Special Features:
- Robust Membrane: Uses "Complex Thermally Induced Phase Separation" (c-TIPS) technology for high crystallinity, exceptional chemical resistance, mechanical strength, and longer lifetime.
- Permanently Hydrophilic Membrane: Ensures steady flux by fixing hydrophilicity permanently through an innovative cross-link technology, preventing loss of hydrophilicity.
- Low Operation Pressure: Designed to run at pressures as low as 0.02 MPa (3.0 psi).
- Oxidation-inert Membrane: PVDF polymer allows thorough cleaning with strong oxidants.
- Internal Air Channels: Individual air diffusers below each module ensure even air bubbling to scrub away pollutants.
- Soft Potting: A soft layer of potting material protects the "roots" of the capillaries, which are the weakest portions of the membrane modules.
Application:
OLTRE SUB membrane modules are suitable for:
- Waste water treatment by membrane bioreactor process.
- Waste water treatment by enhanced bioreactor process.
- Waste water recovery from waste water.
- Enhanced drinking water treatment.
Operating Limits
- Typical Filtrate Flux: <50 L/m²h (<85 GDF)
- Maximum Applied Feed Pressure: 0.05 - 0.05 MPa (-7.3-7.3psi)
- Maximum TMP: 0.2 MPa (30psi)
- Maximum Backwash Pressure: 0.2 MPa (30psi)
- CIP Chlorine Concentration: 2000ppm
- Operating Temperature: 10-40°C (50-104°F)
- Operating pH Range: 1-10
- Operation Mode: Outside-in, direct Flow, Cross flow, continues air scrubbing
Typical Process Conditions
- Backwash Flux: 70-150 L/m²h (19-255 GFD)
- Backwash Duration: 30-120 seconds
- Backwash Frequency: 15-60 minutes
- CEB Frequency: 0-24 times per day
- CEB Duration: 2-20 minutes
- Cleaning Chemicals: NaClO, NaOH, HCl, citric acid or oxalic acid
Mechanical / Hydraulic
Module Dimensions:
| Model | A | B | C | D | H | I | O |
|---|---|---|---|---|---|---|---|
| OLTRESUB-0660-M | 1375mm (54.1”) | 1590mm (62.6”) | 95mm (3.7”) | 120mm (4.7”) | 158mm (6.2”) | φ 30mm (φ1.18”) | φ 40mm (φ1.57”) |
| OLTRESUB-0680-M | 1875mm (73.8”) | 2090mm (82.3”) | 95mm (3.7”) | 120mm (4.7”) | 158mm (6.2”) | φ 30mm (φ1.18”) | φ 40mm (φ1.57”) |