Datasheet summary
SEA2-2521
Engineering summary from PDF text extraction for SEA2-2521. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: SEA2-2521
- Type: High Rejection, Excellent Productivity - Sea Water Element
- Configuration: Spiral Wound
- Membrane Polymer: Composite Polyamide
- Brine Spacer Material: Polypropylene
Performance Specifications (Test Conditions)
- Permeate Flow: 275 gpd (1.0 m³/d)
- Salt Rejection: 99.4% nominal (99.2% minimum)
- Nominal Membrane Area: 12 ft² (1.1 m²)
- Test Solution: 32000 ppm NaCl
- Applied Pressure: 800 psi (56 bar)
- Operating Temperature: 77 °F (25 °C)
- Permeate Recovery: 10%
- pH Range: 6.5–7.0
Operating Limits
- Maximum Operating Pressure: 1000 psi (69 bar)
- Maximum Operating Temperature: 113 °F (45 °C)
- Maximum Pressure Drop: 10 psi (0.7 bar)
- Maximum Feed Flow: 6 gpm (23 lpm)
- Maximum Feed Chlorine Concentration: <0.1 ppm
- Maximum Feedwater SDI (15min): 5.0
- Maximum Feedwater Turbidity: 1.0 NTU
- Feedwater pH Range: 3.0–10.0
- Minimum ratio of concentrate to permeate flow for any element: 5:1
Mechanical / Hydraulic
- Total Length (A): 21.0 inches (533.4 mm)
- Diameter (B): 2.4 inches (61 mm)
- Connection Diameter (C): 0.75 inches (19.1 mm)
- Core Tube Extension Feed Side (DF): 1.2 inches (30.5 mm)
- Core Tube Extension Conc. Side (DC): 1.2 inches (30.5 mm)
- Weight: 2 lbs (0.9 Kg)
Important Notices & Guidelines
- Permeate flow for individual elements may vary ±20 percent.
- Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite.
- Permeate obtained from the first hour of operation should be discarded.
- Avoid static permeate-side backpressure at all times.
- These membranes may be subject to drinking water application restrictions in some countries; please check the application status before use and sale.
- For element loading, use only glycerine to lubricate o-rings and brine seal.
- The customer is fully responsible for the effects of incompatible chemicals on elements. The presence of free chlorine and other oxidizing agents will cause membrane failure, and the damage is not covered under warranty.
Disclaimer: This summary is based on the provided text extract. The original PDF datasheet may contain additional figures, footnotes, or more recent revisions. Contractual data for any project must match the specific OEM PDF revision used on that project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.